The energy-saving coefficient K2 (n140) is set to a value that corresponds with that
motor code (n158).
Motor Type
Voltage Class
YASKAWA
General-
purpose
Motor
YASKAWA
Inverter
Motor
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Motor Code
Capacity
Motor Code: n158
0.1 kW
0
0.2 kW
1
0.4 kW
2
0.75 kW
3
200V
1.5 kW
4
2.2 kW
5
3.7 kW
7
5.5 kW
9
7.5 kW
10
0.2 kW
21
0.4 kW
22
0.75 kW
23
1.5 kW
24
400V
2.2 kW
25
3.0 kW
26
3.7 kW
27
5.5 kW
29
7.5 kW
30
0.1 kW
40
0.2 kW
41
0.4 kW
42
0.75 kW
43
200V
1.5 kW
44
2.2 kW
45
3.7 kW
47
5.5 kW
49
7.5 kW
50
0.2 kW
61
0.4 kW
62
0.75 kW
63
1.5 kW
64
400V
2.2 kW
65
3.0 kW
66
3.7 kW
67
5.5 kW
69
7.5 kW
70
Energy-saving
coefficient K2: n140
481.7
356.9
288.2
223.7
169.4
156.8
122.9
94.8
72.7
713.8
576.4
447.4
338.8
313.6
245.8
245.8
189.5
145.4
481.7
356.9
300.9
224.7
160.4
138.9
106.9
84.1
71.7
713.8
601.8
449.4
320.8
277.8
213.8
213.8
168.3
143.3
109