Cu-Gh08 Control Unit Signals - DeDietrich AMC 15 Installation And Service Manual

Wall-hung gas condensing boilers
Table of Contents

Advertisement

Code
Text display
AC004
Burner Starts
AC026
Pump running hours
AC027
Pump starts
DC002
DHW valve cycles
DC003
Hrs DHW 3wv
DC004
DHW burner starts
DC005
DHW burning hours
GC007
Failed starts
PC001
ChCtrTotalPowerCons.
PC002
Burner starts total
PC003
Hrs Burning total
PC004
Burner flame loss
Tab.72
On >
> Installation Setup > CU-GH08 > > DHW ( Internal DHW ) > Parameters, counters, signals > Signals
Code
Text display
DM029
DHW setpoint
Tab.73
On >
> Installation Setup > CU-GH08 > DHW ( Internal DHW ) > Parameters, counters, signals > Signals
Code
Text display
Anti legionella act.
AM001
DHW active
AM010
Pump speed
AM016
System Flow Temp
AM018
T return
AM040
Control temperature
DM002
DHWFlowSpeed
DM005
DhwSolarTankTemp
DM008
DHW out temp
7686707 - v.01 - 06092018
Description
Number of generator startings since the
previous servicing.
Counter that shows the number of pump
running hours
Counter that shows the number of pump
starts
Numbers of Domestic Hot Water
diverting valve cycles
Number of hours during which the
diverting valve is in DHW position
Number of burner starts for Domestic
Hot Water
Number of burning hours in Domestic
Hot Water
Number of failed starts
Total power consumption used by
Central Heating
Total number of burner starts. For
heating and domestic hot water
Total number of burning hours. For
heating and domestic hot water
Number of burner flame loss
9.6.2

CU-GH08 control unit signals

Description
Domestic Hot Water temperature
setpoint
Description
Anti legionella is active
Is the appliance currently in domestic hot
water production mode?
The current pump speed
Flow temperature of appliance.
Return temperature of appliance. The
temperature of the water entering the
appliance.
Temperature used for hot water control
algorithms.
Actual DHW combi flow rate
Domestic Hot Water solar tank
temperature
Temperature sensor for the tap
temperature leaving the appliance
Range
0 - 4294967294
0 Hours - 65534 Hours
0 - 65534
0 - 4294967294
0 Hours - 65534 Hours
0 - 65534
0 Hours - 65534 Hours
0 - 65534
0 kW - 4294967294 kW
0 - 4294967294
0 Hours - 65534 Hours
0 - 65534
Range
0 °C - 100 °C
Range
0 = Off
1 = On
0 = Off
1 = On
0 % - 100 %
-25 °C - 150 °C
-25 °C - 150 °C
0 °C - 250 °C
0 l/min - 25 l/min
-25 °C - 150 °C
-25 °C - 150 °C
9 Settings
AMC
93

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amc 25/28 miAmc 25Amc 35

Table of Contents