Installation Instructions for Trove2CV2 (TCV2):
1. Fasten standoffs onto metal pems configuration (A) or configuration (B) of enclosure depending on the
sub-assembly module (Fig. 6, pg. 7).
2. Position sub-assembly module over corresponding standoffs and secure module into enclosure with
four (4) pan head screws supplied (Fig. 6a, pg. 7).
3. Refer to the Trove2 Installation Guides and individual Sub-Assembly Installation Guides for the
following models: ACM4(CB), ACM8(CB), LINQ2, LINQ8PD(CB), MOM5, PD4UL(CB), PD8UL(CB),
PD16W(CB), PDS8(CB), ACMS8(CB), VR6 for further installation instructions.
Sub-Assembly Position Chart for the Following Models:
Sub-Assembly
Module
ACM8(CB)
ACMS8(CB)
LINQ2**
LINQ8PD(CB)
ACM4(CB)
MOM5
PD4UL(CB)
PD8UL(CB)
PD16W(CB)
PDS8(CB)
VR6
* Top left position (A) is usually reserved for Altronix power
supplies, but can also be used for sub-assemblies (Fig. 6).
** LINQ2 can be installed when utilizing
eFlow power supply/charger boards.
Fig. 6a
Pan Head
Screw
Sub Assembly
Sub-Assembly
Mounting
Mounting
Position
First, Second &
Third on Left
Top Edge
Two (2)
Vertical Slots
Third on Left
Pem
Standoff
Enclosure
A *
C
B
A
A
B
B
A
Fig. 6
C
- 7 -