ACM8 & ACM8CB
Access Power Controllers
Installation Guide
Models Include:
• ACM8
-
Fused Outputs
• ACM8CBE
-
PTC Outputs
• ACM8E
-
Fused Outputs
• ACM8CB
-
PTC Outputs
Rev. 092503

Advertisement

Table of Contents
loading

Summary of Contents for Altronix ACM8

  • Page 1 ACM8 & ACM8CB Access Power Controllers Installation Guide Models Include: • ACM8 • ACM8E Fused Outputs Fused Outputs • ACM8CBE • ACM8CB PTC Outputs PTC Outputs Rev. 092503...
  • Page 2: Specifications

    These units convert one (1) 12 to 24 volt AC or DC input into eight (8) independently controlled fused or PTC protected outputs. These power outputs can be converted to dry form “C” contacts (ACM8 & ACM8E only). Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc.
  • Page 3: Installation Instructions

    3. Output options (Fig. 1, pg. 4): The ACM8/ACM8E will provide either eight (8) switched power outputs, eight (8) dry form “C” outputs, or any combination of of both switched power and form “C” outputs, plus eight (8) unswitched auxiliary power outputs.
  • Page 4: Typical Application Diagram

    PANEL N.O. DOOR RELEASING DEVICE FACP Dry FACP Form "C" OUTPUT Output (Fire Alarm RELAY Control Panel) ALTRONIX CORP. BKLYN, NY 11220 ACCESS POWER IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND...
  • Page 5: Led Diagnostics

    (When using AC power supplies polarity need not be observed), NC, C, NO become form “C” 5 amp 24VAC/VDC rated dry outputs when fuses are removed (ACM8/ACM8E). Contacts shown in a non-triggered state. FACP INTERFACE Fire Alarm Interface trigger input from FACP. Trigger inputs can be normally open, T, + INPUT - normally closed from an FACP output circuit (Fig.
  • Page 6: Hookup Diagrams

    CUT JUMPERS JUMPER J3 J1 AND J2 FACP OUTPUT EOL ISOLATED POWER INPUT 12 OR 24 VAC OR VDC (ACM8 POWER) FROM FACP OUTPUT ISOLATED POWER INPUT CIRCUIT 12 OR 24 VAC OR VDC (LOCK POWER) Fig. 5 Normally Open FACP Latching trigger input Fig.
  • Page 7 Enclosure Dimensions (ACM8E/ACM8CBE): 13”H x 13.5”W x 3.25”D 3.25" TOP ONLY 1.1875" 12.5" 3.25" 1.1875" .75" 1.5" 6.25" 11" 11.75" 1.1875" 3.25" .81" 1.4" 1.4" 5.5" 6.5" 11.66" 12.1" 13" - 7 -...
  • Page 8 Notes: Altronix is not responsible for any typographical errors. Altronix Corp. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IIACM8/ACM8CB series I01D MEMBER - 8 -...
  • Page 9 BarcodesInc 200 West Monroe Street Chicago, Illinois 60606 Phone: 1-800-351-9962 Fax: 1-312-212-1800 www.barcodesinc.com About BarcodesInc BRANDS Who We Are BarcodesInc is North America's leading provider of We Owe Our Success To You Why Choose BarcodesInc? Dedicated Account Our Account Managers will not compromise when it comes to providing you top-notch service. Your Account Manager is the primary point of contact for your business and makes it a priority to get to know you, your company and all your needs.