THREADED STRAIGHT FITTING TORQUE VALUE (RIGID TUBE)
FLARED END
STRAIGHT END
TUBE
ALUMINUM
ALUMINUM
STEEL
6061-0 ALUMINUM
STEEL
6061-T(X) ALUMINUM
OUTSIDE
On Oxygen Lines
5052-0 ALUMINUM
w/ steel sleeve
DIAMETER
Torque-Limits
Torque-Limits
Torque-Limits
Torque-Limits
Torque-Limits
Torque-Limits
in-lbs.
in-bs.
inlbs.
in-lbs.
in-lbs.
in-bs.
MIN.
MAX.
MIN.
MAX.
MIN.
MAX.
MIN.
MAX.
MIN.
I MAX.
TUBE WALL
MIN.
MAX.
18
20
30
45
55
316
90
100
30
40
90
100
0.028
45
55
14
40
65
135
150
40
65
135
150
0.022
80
105
0.028
80
105
0.035
80
105
0.049
90
115
516
60
80
100
125
180
200
60
80
180
200
0.028
80
105
0.035
80
105
0.042
125
175
38
75
125
270
300
75
125
270
300
0.028
125
175
0.035
125
175
0.049
125
175
12
150
250
450
500
150
250
450
500
0.028
135
180
0.035
200
300
0.049
400
500
0.058
400
500
0.065
400
500
58
200
350
700
800
200
350
700
800
All
500
600
34
300
500
1100
1150
300
500
1100
1150
All
600
700
1
500
700
1200
1400
500
700
1200
1400
All
1000
1300
1-1 4
600
900
1300
1450
600
900
1300
1450
All
1300
1500
1-1 2
600
900
1350
1500
600
900
1350
1500
All
1400
1700
2
600
900
1500
1700
Table 1-4. Torque Values - Straight Threaded Fittings (Line)
1-8.
SAFETYING PROCEDURES. The use of safety
2.
Copper that is cadium-plated and dyed yellow
wire, cotter pins, lockwashers, and self-locking nuts
is used for shear and seal wiring applications.
is to prevent relative movement of critical components
(a)
Shear applications are those where it is
subject to vibration, torque, tension, etc., which could
necessary to break or shear wire to permit operation
cause attaching parts to be broken, loosened, and/or
or actuation of emergency devices.
detached.
(b)
Seal applications are where wire is used
with a lead seal to prevent tampering or use of a
1-9.
SAFETY WIRE PROCEDURES.
device without indication.
a.
Identification. Lockwire comes in three types
3.
Aluminum Alloy (Alclad 5056) is dyed blue
which are identified by size and color. The three types
and is used exclusively for safety-wiring magnesium
are classified by use.
parts.
1. Inconel and Monel wire is used for general
4.
Size of wire is dependent on material and
lockwiring and is identified by a natural wire color.
purpose of installation.
(a) Inconel can withstand temperatures up to
(a)
0.020-inch diameter copper wire should be
1500°F.
used for shear and seal application.
(b)
Monel can withstand temperatures up to
(b)
0.020-inch diameter wire may be used to
800°F.
lockwire parts with tie holes smaller than 0.045 in-
1-8