MODEL 182 & T182 SERIES SERVICE MANUAL
CESSNA PROGRESSIVE CARE
MODEL 182 & T182
OPERATION NO. 4
Registration No.
Airplane Model and SN
Airplane Time
INSPECTION COMPLETED BY
A
1 Placards and Decals - Inspect presence, legibility, and
security. Consult Pilot's Operating Handbook and FAA-
Approved Airplane Flight Manual for required placards.
B
1 Fuselage Surface - Inspect for skin damage, loose rivets.
condition of paint. and check pitot-static ports and drain
holes for obstruction. Inspect covers and fairings for
security.
B
2 Internal Fuselage Structure - Inspect bulkheads, doorposts.
stringers, doublers, and skins for corrosion, cracks,
buckles, and loose rivets, bolts and nuts.
B
3 Control Wheel Lock - Check general condition and
operation.
B
4 Fuselage Mounted Equipment - Check for general condition
and security of attachment.
B
5 Antennas and Cables - Inspect for security of attachment.
connection, and condition.
B
6 Emergency Locator Transmitter - Inspect for security of
attachment and check operation by verifying transmitter
output. Check cumulative time and useful life of batteries
in accordance with FAR Part 91.207. Refer to Section 16 -
Emergency Locator Transmitter - Checkout Interval.
B
7 Instument Panel Shock Mounts, Ground Straps, and
Covers - Inspect for deterioration, cracks, and security of
attachment.
B
8 Pilot's and Copilot's Inertia Reels - Inspect for security of
installation, proper operation. and evidence of damage.
B
9 Seats. Seat Belts, and Shoulder Harnesses - Check general
condition and security. Check operation of seat stops and
adjustment mechanism
Inspect belts for condition and
security of fasteners.
B
10 Windows. Windshield. Doors, and Seals - Inspect general
condition. Check latches, hinges. and seals for condition.
operation. and security of attachment.
B
12 Flight Controls - Check freedom of movement and proper
operation through full travel with and without flaps
extended. Check electric trim controls for operation (as
applicable.)
B
14 Portable Hand Fire Extinguisher - Inspect for proper
operating pressure. condition, security of installation, and
servicing date.
B
15 Seat Tracks and Stops - Inspect seat tracks for condition
and security of installation. Check seat track stops for
damage and correct location. Ensure inspection of seat
rails for cracks EACH 50 HOURS. Refer to Section 3.
B
16 Control Column - Inspect pulleys, cables. sprockets.
bearings, chains. bungees. and turnbuckles for condition
and security.
B
17 Fuel Line and Selector Valve Drain(s) - Remove plug and
drain.
C
9 Elevator/Rudder Downspring - Check structure, bolts.
linkage, bellcrank. and push-pull tube for condition,
operation. and security Check cables for tension, routing.
fraying. corrosion, and turnbuckle safety Check travels if
cables require tension adjustment or if stops are damaged
2-64