Parameters - Gira 5112 00 Product Documentation

Push button sensor 3 basic 1-gang, push button sensor 3 basic 2-gang (1+1), push button sensor 3 basic 3-gang
Hide thumbs Also See for 5112 00:
Table of Contents

Advertisement

4.2.4 Parameters

Description
h General
Light period of status
LED for button-press
indicator
Function of
operation LED /
Labelling field
illumination
h Rocker 1
Function
These parameters are only visible for the function "Switching"...
Function of status LED
Command on pressing
left rocker
Command on pressing
right rocker
Order No. 5111 00
Order No. 5112 00
Order No. 5113 00
Values
1 sec
2 sec
3 sec
4 sec
5 sec
Always OFF
Always ON
No function
Switching
Dimming
Venetian blind
Value transmitter
Scene extension
Always OFF
Always ON
Button-press display
Status display
(of the switching object)
Inverted status display
(of the switching display)
No function
ON
OFF
TOGGLE
No function
ON
OFF
TOGGLE
Software "Push button sensor 3 basic"
Comment
This parameter defines the switch-on
time the status LED is lit up to indicate
actuation. The setting concerns all
status LEDs whose function is set to
"Button-press display".
Specifies the state of the operation LED
or the labelling field illumination.
This parameter is used to define the
basic function of the rocker.
Specifies the control of the status LED.
Defines the command when the left
rocker button is pressed.
Defines the command when the right
rocker button is pressed.
Parameters
Page 18 of 23

Advertisement

Table of Contents
loading

This manual is also suitable for:

5111 005113 00

Table of Contents