Table of Contents

Advertisement

10.1.1

Tests

EMC tests
Electrostatic discharge immunity test (EN61000-4-2)
Electrostatic discharge immunity test (ISO10605:2008)
Electromagnetic field immunity test (EN61000-4-3)
Electrical fast transient/burst immunity test (EN61000-4-4)
Surge immunity test (EN61000-4-5)
Induced disturbances immunity test (EN61000-4-6)
Magnetic field immunity test (EN61000-4-8)
Conducted Emissions (CISPR 16-2)
Radiated Emissions (CISPR 16-2)
Electromagnetic field immunity test (ISO11452-4)
Electrical transient immunity test on supply lines (ISO7637-2)
Conducted Transient Emissions (ISO 7637-2)
Radiated Emissions (CISPR 25)
FCC Part 15/47 CFR Ch. I
Electrical loads
ISO 16750-2 (Code AE. Level IV)
Temperature / climate tests
Temperature cycle EN 60068-2-14 Nb: 2010-04
Temperature shock EN 60068-2-14 Na: 2010-04
Damp heat, cyclic EN 60068-2-30 Db: 2006-06
PROEMION GMBH, Phone: +49 661 9490-600, Fax: -666, info@proemion.com, proemion.com
CANlink GSM / UMTS 5xxx Device Manual
PRELIMINARY
10 Certifications
Value
6 kV Contact discharge
8 kV Air discharge
Operation:8 kV contact and
15 kV air discharge
Handling: 8 kV contact and
air discharge
10 V/m (80 - 1000 MHz)
3 V/m (1.4 - 2.7 GHz)
Supply Line: 2 kV
Signal Line: 1 kV
Supply Line: 0.5 kV
10 V
30 A/m
Class B
Class B
60mA (20 - 80 MHz)
30 V/m (80 - 1000 MHz)
Test pulse 1, 2a/b, 3a/b, 4, 5a
Class B
Value
Value
-30°C...+75°C
10 cycles
-40°C...+85°C
10 cycles
+55°C, 95% rH
2 cycles
85