Troubleshooting

Problem
CANlink GSM / UMTS 5xxx does not
work properly.
Direct communication with the device is
not possible.
Tab. 5-2
Troubleshooting
CANlink GSM / UMTS 5xxx Device Manual
PRELIMINARY
What to do
► Check if the CAN baud rate is set
correctly
► Check if the wiring is correct
(connector pinning)
► Check if the CAN network is
terminated correctly:
measuring 60 Ohms between
CAN-H and CAN-L & at least one
termination resistor in a desk
network
► Check if the CAN receive objects
are configured correctly and
activated
► Check if the CAN filter settings in
the RMsys Configurator are
selected correctly.
► In the Communication Settings
(
Options > Settings >
Communication Settings
CAN Filter Settings > Driver-
optimized settings
► Select
Totally open for 11 and
.
29 bit messages
5 Operation
), select
.
73