Preparation Of Fire; Remove Outer Case; Fit Flue - Valor 474 Valentia Installation And Owner's Manual

Balanced flue room sealed radiant / convector gas fire
Table of Contents

Advertisement

Note:It is not necessary to allow for shrinkage of timber frames in existing
buildings where the necessary length of time has elapsed to allow for any contraction
of the timber frame.
7.1

Remove Outer Case

(a)
Remove the door mask by first lifting upwards to clear the retaining pins and
then swinging it out from the fire bottom first.
(b)
Pull off the control knob.
(c)
Remove the four screws, two either side of the fire securing the outer case.
(d)
Lift the outer case away from the fire and put in a safe place.
(e)
Remove the glass door by removing the wingnuts on the door surround. Lift off
the glass door and put in a safe place.
7.2

Fit Flue

(a)
Place the heater face down taking care to protect any soft surface.
(b)
Fit the flue and air ducts to the back of the heater using the gaskets and screws
provided. This operation is made easier by using the screws to tap the holes before
assembly. The four screws for the flue duct are already fitted to the fire. The flanges
of the ducts are marked 'TOP' to indicate the way in which the ducts are to be fitted.
Note: Do not remove the two middle slotted screws.
©
GDC Group Ltd. 2014
INSTALLER GUIDE

7. PREPARATION OF FIRE

Page 17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents