Siwarex Wl270 Cp-S Sb - Siemens SIWAREX WL200 Series Operating Instructions Manual

Load cell
Hide thumbs Also See for SIWAREX WL200 Series:
Table of Contents

Advertisement

Variable
Temperature coefficient
Characteristic value T
Zero signal T
Min. initial loading E
Maximum working load L
Break load L
Maximum lateral load L
Rated measuring path h
Recommended supply voltage
Rated characteristic value C
Tolerance of zero signal D
Input resistance R
Output resistance R
Insulation resistance R
Rated temperature range B
Operating temperature range B
Storage temperature range B
Sensor material
Degree of protection according to EN 60 529
Cable connection
Output is current-calibrated
*
9.1.12

SIWAREX WL270 CP-S SB

Table 9- 12
Variable
Type series
Designation
Construction type
Possible applications
Rated load E
Accuracy class according to OIML R60
Max. scale interval n
Min. scale interval V
Combined error F
Deviation F
Creep error F
30 min
SIWAREX WL200
Operating Instructions, 07/2016, A5E02199611B-03
Kc
Ko
min
u
d
lq
at E
n
max
Rated
o
i
o
is
tn
tu
ts
Technical data SIWAREX WL270 CP-S SB
max
LC
min
comb
V
cr
9.1 Functional data
Value
0.017% C
/ 10 K
n
0.023% C
/ 10 K
n
0 kg
150% E
max
150% E
max
75% E
max
0.5 mm
5 to 12 V DC
2.0 ± 0.02 mV/V
*
< ± 1.0% C
n
700 ± 7 Ω
700 ± 7 Ω
5000 MΩ at 50 V DC
- 10 ... + 40 °C
- 35 ... + 65 °C
- 35 ... + 65 °C
Stainless steel
IP68
Four-core, shielded
15 m
Value
WL270
CP-S SB
Compression load cell
Container weighers
100 t
C3
3000
E
/ 9000
max
± 0.02% C
n
± 0.02% C
n
0.023% C
n
Technical data
57

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Siwarex wl260 sp-s aaSiwarex wl260 sp-s abSiwarex wl260 sp-s aeSiwarex wl260 sp-s saSiwarex wl260 sp-s sbSiwarex wl260 sp-s sc ... Show all

Table of Contents