Siwarex Wl260 Sp-S Ae - Siemens SIWAREX WL200 Series Operating Instructions Manual

Load cell
Hide thumbs Also See for SIWAREX WL200 Series:
Table of Contents

Advertisement

Variable
Sensor material
Degree of protection according to EN 60 529
Maximum tightening torque of the fixing screws
Cable connection
Type approval to OIML for SIWAREX WL260 SP-S AB available soon
1)
9.1.3

SIWAREX WL260 SP-S AE

Table 9- 3
Variable
Type series
Designation
Construction type
Possible applications
Rated load E
Accuracy class
Combined error F
Deviation F
Creep error F
30 min
Temperature coefficient
Characteristic value T
Zero signal T
Min. initial loading E
Maximum working load L
Break load L
Maximum lateral load L
Recommended supply voltage
Rated characteristic value C
Tolerance of zero signal D
Input resistance R
Output resistance R
Insulation resistance R
Rated temperature range B
Operating temperature range B
Storage temperature range B
Sensor material
Degree of protection according to EN 60 529
SIWAREX WL200
Operating Instructions, 07/2016, A5E02199611B-03
Technical data SIWAREX WL260 SP-S AE
max
comb
V
cr
Kc
Ko
min
u
d
lq
Rated
o
i
o
is
tn
t
ts
9.1 Functional data
Value
Aluminum
IP65
35 ... 40 Nm
Six-core, shielded
3 m
Value
WL260
SP-S AE
Single-point load cell
Small platform scales and small convey-
or scales
0.3; 0.6; 1; 1.2; 1.5; 3.0 kg
0.015 %
± 0.015% C
n
± 0.017% C
n
≤ ± 0.015% C
n
≤ ±0.03% C
/ 10 K
n
≤ ±0.03% C
/ 10 K
n
0 kg
120% E
max
300% E
max
250% E
max
5 ... 12 V DC
2.0 ± 0.2 mV/V
< ± 2.0% C
n
406 ± 6 Ω
350 ± 3 Ω
5000 MΩ at 50 V DC
-10 to +40 °C
-20 to +50 °C
-20 to +20 °C
Aluminum
IP65
Technical data
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Siwarex wl260 sp-s aaSiwarex wl260 sp-s abSiwarex wl260 sp-s aeSiwarex wl260 sp-s saSiwarex wl260 sp-s sbSiwarex wl260 sp-s sc ... Show all