Siwarex Wl270 K-S Ca - Siemens SIWAREX WL200 Series Operating Instructions Manual

Load cell
Hide thumbs Also See for SIWAREX WL200 Series:
Table of Contents

Advertisement

Variable
Min. initial loading E
Maximum working load L
Break load L
Maximum lateral load L
Rated measuring path h
Recommended supply voltage
Rated characteristic value C
Tolerance of zero signal D
Input resistance R
Output resistance R
Insulation resistance R
Rated temperature range B
Operating temperature range B
Storage temperature range B
Sensor material
Degree of protection according to EN 60 529
Cable connection
Output is current-calibrated
*
9.1.14

SIWAREX WL270 K-S CA

Low temperature range (≤ 130 °C)
Table 9- 14
Technical data SIWAREX WL270 K-S CA low temperature range
Variable
Type series
Designation
Construction type
Possible applications
Rated load E
max
Accuracy class
Combined error F
comb
Hysteresis
Dead load output return
Creep error F
cr
SIWAREX WL200
Operating Instructions, 07/2016, A5E02199611B-03
min
u
d
lq
at E
n
max
Rated
o
i
o
is
tn
tu
ts
30 min
20 to 30 min
Value
0 kg
150% E
300% E
10% E
0.36 mm
5 to 12 V DC
2.0 ± 0.02 mV/V
< ± 1.0% C
450 ± 5 Ω
480 ± 5 Ω
5000 MΩ at 50 V DC
- 10 ... + 40 °C
- 35 ... + 65 °C
- 35 ... + 65 °C
Stainless steel
IP68
Four-core, shielded
20 m
Compression load cell
Container and bin scales
2.8; 6; 13; 28; 60; 130; 280 t
0.1%
≤ ± 0.10% C
n
≤ ± 0.05% C
n
≤ ± 0.05% C
n
≤ ± 0.0600% C
n
≤ ± 0.0150% C
n
Technical data
9.1 Functional data
max
max
max
*
n
Values
WL270
K-S CA
350 t, 500 t
0.2 %
≤ ± 0.20% C
≤ ± 0.10% C
≤ ± 0.07% C
≤ ± 0.0800% C
≤ ± 0.0200% Cn
n
n
n
n
59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Siwarex wl260 sp-s aaSiwarex wl260 sp-s abSiwarex wl260 sp-s aeSiwarex wl260 sp-s saSiwarex wl260 sp-s sbSiwarex wl260 sp-s sc ... Show all

Table of Contents