Technical data
9.1 Functional data
Variable
Sensor material
Degree of protection according to EN 60 529
Maximum tightening torque of the fixing screws
Cable connection
9.1.2
SIWAREX WL260 SP-S AB
Table 9- 2
Variable
Type series
Designation
Construction type
Possible applications
Rated load E
Accuracy class according to OIML R60
Max. scale interval n
Min. scale interval V
Combined error F
Deviation F
Creep error F
30 min
Temperature coefficient
Characteristic value T
Zero signal T
Min. initial loading E
Maximum working load L
Break load L
Maximum lateral load L
Rated measuring path h
Recommended supply voltage
Rated characteristic value C
Tolerance of zero signal D
Input resistance R
Output resistance R
Insulation resistance R
Rated temperature range B
Operating temperature range B
Storage temperature range B
46
Technical data SIWAREX WL260 SP-S AB
max
LC
min
comb
V
cr
Kc
Ko
min
u
d
lq
at E
n
max
Rated
o
i
o
is
tn
t
ts
Value
Aluminum
IP65
15 ... 20 Nm
Six-core, shielded
3 m
Value
WL260
SP-S AB
Single-point load cell
Platform scales,
small conveyor scales
50; 100; 200; 500 kg
C3
1)
3000
E
/ 10000
max
± 0.02% C
n
± 0.017% C
n
0.02% C
n
0.014% C
/ 10 K
n
0.017% C
/ 10 K
n
0 kg
150% E
max
300% E
max
100% E
max
≤ 1.22 mm
5 to 12 V DC
2.0 ± 0.2 mV/V
< ± 2.0% C
n
409 ± 6 Ω
350 ± 3 Ω
5000 MΩ at 50 V DC
- 10 ... + 40 °C
- 35 ... + 65 °C
- 35 ... + 65 °C
Operating Instructions, 07/2016, A5E02199611B-03
SIWAREX WL200