4.3

Dismantling

For the disassembly of load cells, the same safety rules and requirements apply as for
installation and assembly.
1. Disconnect all the supply voltages and auxiliary voltages.
2. Secure the load carrier against falling.
3. Use appropriate hoisting gear and tools.
4. Take the load off the load cell.
5. Carefully remove the load cell without using force. Do not pull on the cable of the load
cell.
6. Do not cut the cable if the load cell is to be re-used or sent in for repair.
7. Do not carry the load cell by the cable.
SIWAREX WL200
Operating Instructions, 07/2016, A5E02199611B-03
Installing
4.3 Dismantling