4 – Common
The common connection used as a reference point with the integrator.
GND – Ground
A ground connection. Do not use this ground for the cable shield.
Notes:
•
Ground the cable shield at the integrator end only!
•
For optimal performance the housing of the Speed Sensor must be connected
to a reliable earthed ground.
Terminal Connections to Siemens Milltronics Integrators
WS300
standard
Milltronics BW100
Milltronics BW500
Terminal Connections to SIWAREX FTC Integrator
WS300
(standard)
SIWAREX FTC
Note:
•
N/C indicates the terminal is not normally connected.
Determine the pulley shaft rotation on the end of the pulley shaft to which the WS300 is
attached.
If the pulley shaft rotates clockwise, connect the appropriate wire to terminal 2.
If the pulley shaft rotates counter-clockwise, connect the appropriate wire to terminal 3.
WARNING: Do not connect terminals two and three at the same
time.
7ML19985ML01
SITRANS WS300 Speed Sensor – OPERATING INSTRUCTIONS
1
2
+V
CW
8
7
19
16
1
2
+V
CW
24 V
X1.9
(backplane
(CI+)
bus)
3
4
CCW
Cmn
7
6
16
17
3
4
CCW
Cmn
X1.10
X1.9
(CI- and
(CI+)
Common)
GND
N/C
N/C
GND
N/C
Page 13