Technical data
9.1 Functional data
Variable
Rated load E
Accuracy class according to OIML R60
Max. scale interval n
Min. scale interval V
For E
For E
Combined error F
Creep error F
30 min
Temperature coefficient
Characteristic value T
Zero signal T
Min. initial loading E
Maximum working load L
Break load L
Maximum lateral load L
Rated measuring path h
Recommended supply voltage
Rated characteristic value C
Tolerance of zero signal D
Input resistance R
Output resistance R
Insulation resistance R
Rated temperature range B
Operating temperature range B
Storage temperature range B
Sensor material
Degree of protection according to EN 60 529
54
max
LC
min
= 100; 250; 500 kg; 1; 2 t
max
= 3; 5; 10 t
max
comb
cr
Kc
Ko
min
u
d
lq
at E
n
max
Rated
o
i
o
is
tn
ts
tu
Operating Instructions, 07/2016, A5E02199611B-03
Value
100; 250; 500 kg
1; 2; 3; 5; 10 t
C3; C4; C5
3000; 4000; 5000
E
/ 10000; 15000; 20000
max
E
/ 10000; 15000; 18000
max
± 0.015% C
n
± 0.015% C
n
0.03 % C
/ 10 K
n
0.03 % C
/ 10 K
n
0 kg
150 % E
max
300 % E
max
100% E
max
100 kg: 0.17 mm
250 kg: 0.15 mm
500 kg: 0.32 mm
1 t: 0.63 mm
2 t: 1.2 mm
3 t: 0.9 mm
5 t: 0.6 mm
10 t: 0.8 mm
5 to 12 V DC
3.0 ± 0.003 mV/V
1)
< ± 1.0% C
n
350 ± 3.5 Ω
350 ± 3.5 Ω
5000 MΩ at 50 V DC
-10 to +40 °C
-35 to +65 °C
-40 to +80 °C
Steel, nickel-plated
IP67
SIWAREX WL200