Externals:
- Enclosure .................................................................................................................................. IP 55 (IP56, IP66)
Please see special conditions for frequency range for IP 66 motors at the end of this section.
- Vibration test ................................................................................................................. (IEC 68 see page 93) 1 g
- Max. relative humidity .............................................................. 95 % (IEC 68-2-3) for storage/transport/operation
- Ambient temperature ............................................................................ Max. 40°C (24-hour average max. 35°C)
see Derating for high ambient temperature
- Min. ambient temperature in full operation ..................................................................................................... 0°C
- Min. ambient temperature at reduced performance ................................................................................... -10°C
- Temperature during storage/transport .......................................................................................... -25 - +65/70°C
- Max. altitude above sea level .................................................................................................................... 1000 m
see Derating for air pressure
- EMC standards applied, Emission ................... EN 61000-6-3/EN 6100-6-4, EN 61800-3, EN 55011, EN 55014
- EMC standards applied, Immunity ................................................................................................................... EN
61000-6-2, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, ENV 50204
- Safety standards applied, ..................................................................... EN 60146, EN 50178, EN 60204, UL508
NB!:
Please note that the normal IP 66 solution
is only intended for speed up to maximum
3000 rpm. If higher speed is needed, please
give notification when ordering.
Protection:
Thermal overload protection of motor
and electronics.
Monitoring of the intermediate circuit voltage
ensures that the inverter cuts out if the intermediate
circuit voltage gets too high or too low.
If a mains phase is missing, the inverter will cut
out when a load is placed on the motor.
Terminal arrangement (for installation see quick setup, MG.03.AX.62)