The System is intended for use in the electromagnetic environment specified below. The
customer or the user of the System should assure that it is used in such an environment.
Immunity Test
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
(alternative
method: IEC
61000-4-21)
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless)
telephones and land mobile radios, amateur radio, AM and FM radio broadcast, and TV
broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic
environment due to fixed RF transmitters, and electromagnetic site survey should be
considered. If the measured field strength in the location in which the System is used exceeds
the applicable RF compliance level above, the System should be observed to verify normal
operation. If abnormal performance is observed, additional measures may be necessary, such
as re-orienting or relocation the System.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Note : These guidelines may not apply in all situations. Electromagnetic propagation is affected
14
EMC Immunity Guidance & Declaration for System
IEC
Complian
60601-1-2
ce Level
Test
Level
3
3 V
VRMS
150kHz to
150kHz to
80 MHz
80 MHz
3 V/m
3 V/m
80 MHz to
80 MHz to
2.5 GHz
2.5 GHz
by absorption and reflection from structures, objects, and people.
Chapter 1 - Introduction
B
S
E
, E
RIGHT
PEED
LITE
Electromagnetic Environment Guidance
Portable
and
mobile
equipment should be used no closer to any part of
the
System,
including
recommended separation distance calculated from
the equation appropriate for the frequency of the
transmitter.
Recommended Separation Distance
3.5
d
P
-------- -
=
3
(see
Table
1-10)
3.5
d
P
-------- -
=
3
80 MHz to 800 MHz (see
7
d
P
-- -
=
3
800 MHz to 2.5GHz (see
where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter
manufacturer and d is the recommended separation
distance in metres (m).
Field strengths from fixed RF transmitters, as
determined by an electromagnetic site survey
should be less than the compliance level in each
b
frequency range
.
Interference may occur in the vicinity of equipment
marked with the following symbol:
, E
: P
-I
DGE
XCEL
RE
NSTALLATION
RF
communications
cables,
than
the
Table
1-10)
Table
1-10)
a
,
Page 39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brightspeed edgeBrightspeed excel

Table of Contents