Page 2
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Effectivity: The information in this manual applies to the following BrightSpeed Series CT Systems: • BrightSpeed Elite • BrightSpeed Edge • BrightSpeed Excel Page 2...
Page 3
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION IMPORTANT PRECAUTIONS LANGUAGE ПРЕДУПРЕЖДЕНИЕ Това упътване за работа е налично само на английски език. • Ако доставчикът на услугата на клиента изиска друг език, (BG) задължение на клиента е да осигури превод.
Page 4
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION ADVARSEL Denne servicemanual findes kun på engelsk. • Hvis en kundes tekniker har brug for et andet sprog end engelsk, er det (DA) kundens ansvar at sørge for oversættelse.
Page 5
Serviceanleitung gelesen und verstanden zu haben. • Wird diese Warnung nicht beachtet, so kann es zu Verletzungen des Kundendiensttechnikers, des Bedieners oder des Patienten durch Stromschläge, mechanische oder sonstige Gefahren kommen. ΠΡΟΕΙ∆ΟΠΟΙΗΣΗ Το παρόν εγχειρίδιο σέρβις διατίθεται μόνο στα αγγλικά.
Page 6
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 경고 본 서비스 매뉴얼은 영어로만 이용하실 수 있습니다 . • 고객의 서비스 제공자가 영어 이외의 언어를 요구할 경우 , 번역 서비스 (KO) 를 제공하는 것은 고객의 책임입니다 .
Page 7
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION ATENÇÃO Este manual de assistência técnica só se encontra disponível em inglês. • Se qualquer outro serviço de assistência técnica solicitar este manual (PT-PT) noutro idioma, é da responsabilidade do cliente fornecer os serviços de tradução.
Page 8
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION ATENCION Este manual de servicio sólo existe en inglés. • Si el encargado de mantenimiento de un cliente necesita un idioma que (ES) no sea el inglés, el cliente deberá encargarse de la traducción del manual.
Page 9
In performing all electrical work on these products, GE will use its own specially trained field engineers. All of GE’s electrical work on these products will comply with the requirements of the applicable electrical codes.
Page 10
OMISSIONS & ERRORS Customers, please contact your GE Sales or Service representatives. GE personnel, please use the GEMS CQA Process to report all omissions, errors, and defects in this publication. Page 10...
Page 11
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Revision History Revision Date Reason for change 03/30/15 Chapter 7, Section 1.0: Added Rigging statement according to global requirement Chapter 1: 08/15/13 added floor template (P/N5341997) for GT1700 Table in Section 1.0 added Pre-installation Block Diagram in Section 3.0...
Page 12
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Revision Date Reason for change 10/11/10 Chapter 5: Updated Figure 5-1 Equipment EMI “Envelopes” Chapter 6: Updated FLoor Levelness Requirement Chapter 8: Added Warning Message on Section 2.2 and 3.0 11/04/08 Chapter 3: updated option list in Section 1.0...
Page 13
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Revision Date Reason for change 9/30/06 Chapter 1: Added Section 4 Medical Electrical Equipment for EMC. Chapter 4: Added Limited Access Room information. Chapter 5: Deleted Section 4.8 EMC Edition 2 Compliance - duplicate with newly added Chapter 1, Section 4.
Page 14
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Page 14 Revision History...
Page 15
Hole Locations ........................45 Figure 3-1 Base Scanner System with HPower Table ................49 Figure 3-2 BrightSpeed Elite Base Scanner System with GT1700 Table..........50 Figure 4-1 Regulatory Clearance Requirements for BrightSpeed System Configurations ...... 52 Figure 4-2 Minimum Service Clearance ....................64 Figure 4-3...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure 4-23 Typical Scatter Survey (Body Filter) ..................93 Figure 4-24 Fluoro Stand Position ......................94 Figure 4-25 Scatter Plot of Fluoro - Body ....................94 Figure 4-26...
Page 17
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure 9-9 Typical TS6 Warning Light & Door Interlock Connections ........... 155 Figure 9-10 TS6 Room Door Interlock Connections - With a Door Interlock........... 155 Figure 9-11...
Page 18
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Page 18 Table of Figures...
Page 19
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Table of Tables Table 1-1 Schedule Date Commitments ....................32 Table 1-2 General Site Planning ......................33 Table 1-3 References for Specific Site Requirements ................33 Table 1-4...
Page 20
Table 9-2 GEMS Supplied Cables (Optional, Short Run) - UL Information ......... 134 Table 9-3 GE Healthcare Supplied Cables for GOC or TIO (Standard Run) (2281840-5)- UL Information Table 9-4 GE Healthcare Supplied Cables for NIO16 Console (Standard Run) (2281840-14)- UL Information...........................
Page 21
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Table of Contents Table of Contents Chapter 1 Introduction......................27 Section 1.0 Site Readiness....................27 Section 2.0 Responsibility of Purchaser................28 Customer Room Prep Items .................... 28 Purchaser Site Preparation Work ..................
Page 22
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 4.0 Broad-band......................44 Section 5.0 Phone Line (for optional modem) ..............44 Section 6.0 Review ....................... 44 Chapter 3 System Catalog ..................... 47 Section 1.0 Option Catalog Numbers ................. 47 Section 2.0...
Page 23
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 4.0 Short Footprint Consideration ................ 66 Introduction of Short Footprint function................66 Instruction of using Short Footprint function ..............67 Section 5.0 Recommended Layouts................... 69 Control Room Considerations..................69 Storage Cabinet.......................
Page 24
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Temperature (Scan Room & Control Room)..............97 Humidity (Scan Room & Control Room) ................. 98 Other Guidelines ......................98 Section 2.0 Cooling Requirement ..................99 Section 3.0...
Page 25
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Installations within the United States ................118 Zero Clearance Dollies ....................118 Tilting Table Dollies ....................... 118 Installation Outside of the United States................ 118 Section 4.0 Gantry Considerations................... 119 Section 5.0 ......................
Page 26
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Sags, Surges & Transients ................... 129 Grounding ........................129 Section 3.0 Recommended Power Distribution System ..........130 Section 4.0 Ground System ....................132 Chapter 9 Interconnection Data ..................133 Section 1.0...
This direction contains physical and electrical data necessary for planning and preparing a site. Pre-installation work is defined as site preparation for installation of the GE CT scanner. It is the responsibility of the purchaser to arrange and pay for this work. Pre-installation work includes: •...
This may take a week or longer to schedule. • Power available to A1, with provision for Lockout/Tagout at the A1 disconnect If a UPS is required, a GE A1 breaker* will be needed to complete this installation. Refer to the electrical section for more details. NOTICE SERVICE NOTICE: An improperly prepared site (i.e., one that is in a state of construction)
• Reviewed radiation protection section in the Pre-Installation manual • All in room items shown on the final GE Healthcare site print and the final print is on site • No construction in the scan room or neighboring suite areas...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 2.3.1 Meeting Site Ready Requirements The site ready visit will take place at least three days prior to the delivery date. The site ready visit is intended to verify that all of the siting requirement are met and the site is ready for installation.
Must meet all in section 1 and 2 plus these additions reviewed at the site ready visit. The GE Healthcare project manager will review the site delivery process with you to determine how to best transfer the equipment from the transportation truck to your room.
Table 1-1 Schedule Date Commitments Cust Dates Has the project schedule been verified with facilities department, contractor, and GE? Will the committed site-ready date be met? Does the completion date for any/all construction meet or preceed the delivery date? Is the Power & Ground survey complete?Date: __________________ Hospital contact: ___________________________________________________ Site-Ready visit is scheduled.Date: __________________...
Do the actual room dimensions match those on the final drawings? Has the radiologist health physician reviewed and approved the room layout and shielding requirements? Have any additional requirements or questions about the installation been discussed with GE? List: ___________________________________________________________...
Have the following peripheral locations been included in the site drawings? EKG monitor___ Injector control___ Laser camera ___ UPS ___ 2 Monitor___ Will GE Healthcare provide additional services per contract negotiations? Are correct length cables on order? Table 1-5 Network Connections...
Page 35
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Table 1-6 Miscellaneous Tasks Cust Other Must be completed before the scheduled delivery date Will acceptance/performance testing or bio-medical testing be required?No__ Yes __ Date: ___________ Are trash and/or recycling bins available for the removal of papers, boxes, etc.
Page 36
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Page 36 Chapter 1 - Introduction...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 4.0 Medical Electrical Equipment for EMC General Scope This equipment complies with IEC60601-1-2: 2001+A1: 2004 (ED2.1) and IEC 60601-1-2: 2007 (ED3) (if the system rating plate of the scanner marked with IPX0) EMC standard for medical electrical equipment.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Electromagnetic Immunity Table 1-8 Immunity Declaration EMC Immunity Guidance & Declaration for BrightSpeed System The BrightSpeed System is intended for use in the electromagnetic environment specified below.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Table 1-9 Immunity Declaration con’t EMC Immunity Guidance & Declaration for System The System is intended for use in the electromagnetic environment specified below. The customer or the user of the System should assure that it is used in such an environment.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Table 1-10 Separation Distances Recommended separation distances between portable and mobile RF communications equipment and the BrightSpeed System. The BrightSpeed System is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Installation Requirements & Environment Control : In order to minimize interference risks, the following requirements shall apply. 4.5.1 Cable Shielding & Grounding All interconnect cables to peripheral devices must be shielded and properly grounded. Use of cables not properly shielded and grounded may result in the equipment causing radio frequency interference.
Page 42
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Page 42 Chapter 1 - Introduction...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Chapter 2 Pre-Installation Overview Before a BrightSpeed system can be installed, all pre-installation requirements must be complete. • Chapter 4, Sections • Chapter 5, Environmental Conditions,...
(4) primary leveling pads. The table has five (5) pads used for leveling it. Using the GE print to establish the room layout, make sure all the operating and service clearances shown on the print are observed. Using the template (P/N 5160024/5341997) shipped with the system, locate the anchor holes.
Page 45
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Leveling Pad Leveling Pad GANTRY and Anchor and Anchor Back Ba se Location #2 Location #3 4’ Level or 1M Bubble Level Right Left Leveling Pad Front...
Page 46
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Page 46 Chapter 2 - Pre-Installation Overview...
The following is a list of system options requiring site planning work for the BrightSpeed system. Contact your local GE Medical Systems Sales representative for a complete list of all system options or visit us at www.gehealtcare.com. Refer to the instruction manuals supplied with specific options for respective details.
Page 48
RIGHT PEED LITE XCEL NSTALLATION CATALOG NUMBER OPTION DESCRIPTION B75212BS/B78892AC* ASIR Upgrade Note: The catalog number with * is only for BrightSpeed Elite System with TIO/NIO16 console. Table 3-1 BrightSpeed System Options Page 48 Section 1.0 - Option Catalog Numbers...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 2.0 Base Scanner System Application The CT scanner system includes hardware and software to support patient data acquisition and image analysis for whole-body computed tomography. Configuration The base scanner system is configured as shown.
Page 50
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure 3-2 BrightSpeed Elite Base Scanner System with GT1700 Table Page 50 Section 2.0 - Base Scanner System...
Chapter 4 Room Planning Section 1.0 Required Systems Clearances Consult your local GE Sales and Service Representative about your specific needs. Some possible room size dimensions are shown in the tables below. Recommended Scan Room Typical Scan Room Size Clearance...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 2.0 Regulatory Clearances Regulatory Clearances MINIMUM CLEARANCES UNDER U.S. FEDERAL REGULATIONS AND NATIONAL STANDARDS: 29 CFR 1910 (OSHA), NFPA 70E (STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE), AND NFPA 101 (LIFE SAFETY CODE): Figure 4-1 is a map of clearance requirements for U.S.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 2.1.1 Regulatory Code Description Egress: 29 CFR 1910 Subpart E (OSHA) and NFPA 101 (Life Safety Code) define the minimum requirements for means of egress. The requirement most applicable to equipment installation and room layout is minimum width of exit access.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Work Space Minimum Clear Additional Conditions Requirement Space Head clearance 1981.2 mm (78 in.) This is the height of the workspace measured from the floor at the front edge of the equipment to the ceiling or overhead obstruction(s).
Page 55
(28 in.) provided a written and signed approval is obtained by the local team from the local AHJ (Authority Having Jurisdiction). The signed document must be on file with GE. Direction of Service 711 mm (28 in.) For the front gantry cover removal, a Access (Table Foot) minimum of 457 mm (18 in.) is allowed only...
Page 56
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Work Space Minimum Clear Additional Conditions Requirement Space Direction of Service 914.4 mm (36 in.)* There are no exposed live part hazards with Access (Front of UPS) the cover in place.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 2.1.3 Terms and Definitions Egress: The path of exit from within any room. U.S. regulations require a minimum of 711.2 mm (28 in.) of continuous and unobstructed space, including trip hazards along the path of exit.
Exceptions Rooms smaller than 3353 mm x 6096 mm (11 ft. x 20 ft. ), require construction to meet the minimum requirements. The design center or your GE PMI may have additional recommendations for your room size. 2.2.1.3 Operational Caution In a minimum room layout 356 mm - 686 mm (14 in.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 2.2.2 System Specifications (BrightSpeed) 2.2.2.1 Recommended Room Size This room configuration offers the most flexibility for future upgrades. It has sufficient workspace and space to add millwork, while meeting all regulatory requirements. This room would be compatible with most two-step future installations.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 2.2.3 How to Measure How to measure From the farthest outward component No obstruction areas Measured from gantry covers Gantry Side vertical covers outward Front or back vertical covers outward...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 2.2.4 Minimum Room Size & Requirement Layouts Room A - Less than 711 mm (28 in.) but greater than 256 mm (14 in.) measured from the covers to the left sidewall.
Page 62
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Room B - Less than 36 in. but greater than 28 in. measured from the covers to the left sidewall.In this configuration service, egress and workspace are acceptable around the gantry.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 2.2.5 Recommended Room Size & Requirement Layouts Note: Your room layout may meet the Recommended or Typical room requirements but look different than the room shown below. Contact your sales person to have a detail room layout completed for your site.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 3.0 Service Clearances Servicing of the CT System can be safely performed within the regulatory envelopes defined in Section 2.1 , however sufficient space must be maintained to remove the covers from the system.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Service Clearances for Single Service Engineer • Gantry front cover removal requires the use of the “Tilting Cover Dollies”. These dollies allow the Service Engineer to separate the cover from the gantry, tilt the cover 90 degrees, roll the cover to the foot end of the table, and then tilt the cover an additional 90 degrees such that the front cover is now upside down relative to the normal system mounted condition.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Power Distribution Unit (NGPDU) Service Clearance Positioning of this component must be considered for regulatory compliance as defined in Section 2.1 , Regulated Minimum Working Clearance by Major Subsystem.
, use floor template with ruler to prearrange the layout and calculate the cradle scannable limitation (A). 2.) Make GE siting print to meet regulatory and service clearance requirements. 3.) Record the distance from cradle limitation to wall (X) and cradle scannable limitation (A) for installation.
Page 68
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure 4-4 Short Footprint Calculation diagram A: Cradle Scannable Limitation, the value to be set using Short Footprint function A(Scannable Range(approx.)) = 643mm(Scan Center Line to Gantry Rear Cover) + B(Gantry Rear Cover to Wall) - X(Safety Clearance to prevent hitting cradle to wall).
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 5.0 Recommended Layouts Control Room Considerations Two kinds of Console configurations are available: • Standard Console: Console + Single Piece Desktop; • Console with FWS: Console + Freedom Workspace Table (See Figure 4-6).
Storage Cabinet A storage cabinet is provided by GE Healthcare to store all supplied service equipment (see Table 4-9 for equipment list). This storage cabinet (457 mm D x 914 mm W x 1067 mm H) (18 in.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 6.0 Component Dimensions DESCRIPTION WIDTH DEPTH HEIGHT INCH INCH INCH Color printer Remote Color Monitor (LCD) 16.25 413 Table 4-10 Dimensions of Accessories Table and Gantry...
Page 72
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 3458 [136,1] 803 [31,6] AIR OUT AIR IN 3582 [141] AIR OUT AIR IN Figure 4-8 Gantry shown tilted +30º (top) and -30º (bottom) for BSD Elite/Edge/Excel with...
Page 73
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 2749 (9ft. 1/4in.) AIR OUT SCAN PLANE ISO CENTER CRADLE CENTER AIR IN 3120 (10ft. 2 7/8in.) AIR OUT SCAN PLANE ISO CENTER CRADLE CENTER AIR IN...
Page 74
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 3595 (11ft. 9 1/2in.) AIR OUT SCAN PLANE ISO CENTER CRADLE CENTER AIR IN 3721 (12ft. 2 1/2in.) AIR OUT SCAN PLANE ISO CENTER CRADLE CENTER AIR IN Figure 4-10 Gantry shown tilted +30º...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Power Distribution Unit NOTE: DIMENSIONS ARE IN INCHES (MILLIMETERS). REAR VIEW TOP VIEW AC POWER I/O CONNECTIONS INPUT BOX REAR PANEL REAR VENT AREA AC POWER INPUT BOX FRONT 27.6...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Operator’s Console Wall Figure 4-12 Operator’s Console with Standard Table Page 76 Section 6.0 - Component Dimensions...
Page 77
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Side View Front View AIR IN (10 3/8in.) (1ft. 1 1/8in.) 100(Min) (1ft. 6 1/2in.) (3 7/8in.) (2ft. 5 1/8in.) WALL CLEARANCE Top View (10 3/8in.) (1ft. 6 1/2in.) Figure 4-13 TIO Operator’s Console...
Page 78
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 96 (3.8) 96 (3.8) 470 (18.5) 470 (18.5) 740 (29) Air Out Air In WALL 546 (21.5) 546 (21.5) 832.1 (32.8) 832.1 (32.8) SIDE VIEW SIDE VIEW...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Freedom Workspace Table Height of Freedom Workspace is adjustable. 635 (25”) 89 (3.5”) 210 (8.25”) 538 (21.2”) Seismic Bracket Supplied with FWS Attach seismic brackets to the...
Page 80
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 330 (13.0”) 366 (14.4) 916 (36.1”) 1300 (51.2”) Figure 4-16 Freedom Workspace Table (part 5168666) Page 80 Section 6.0 - Component Dimensions...
Page 81
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION (1ft. 2 7/8in.) (11 1/2in.) (3ft. 1/8in.) 66kg (145.5lbs) 1350 (4ft. 5 1/8in.) Figure 4-17 Freedom Workspace Table Wide (part 5168666-2) Chapter 4 - Room Planning Page 81...
Page 82
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION (1ft. 2 5/8in.) (1ft. 5/8in.) (3ft. 1/8in.) 60kg (132.3lbs) 1300 (4ft. 3 1/8in.) Figure 4-18 Freedom Workspace Table Standard (Narrow) (part 5168666-3) Page 82 Section 6.0 - Component Dimensions...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 7.0 Minimum Dimensions and Clearances Options Ceiling Pedestal mount lowest point to floor (Injector or Monitor) 2134.0 mm (84.0 in) System Operation SYSTEM OPERATION INCHES Finished ceiling to floor (recommended) 2743.0mm...
All other anchoring methods (on floor types other than the 102 mm (4 in.) concrete minimum) must be determined to meet the stated GE minimum load requirements, at the customer’s expense, by their structural contractor. The customer’s contractor is responsible for the installation of all anchors other than those shipped with the system.
Note: If installing the GE BS scanner on a floor type thinner than a 102 mm (4 in. ) concrete floor, the purchaser, at their expense, shall provide acceptable anchoring and mounting methods that meet all structural specifications provided in sections 8.1 through 8.5 of this Pre-Installation Manual.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 8.5.3 Equipment Location To minimize the interference, the CT equipment should be placed on a solid floor, located as far as possible from the following vibration sources: •...
Broad-band is the standard network connection and is required for BrightSpeed Series systems. (A dial-up modem is optional.) A 1000 baseT high-speed network is desired, with 100 baseT network service acceptable. Broad-band connections should use one of the following Category 5 patch cables: CAT Num GE Part Num Length K9000WB 2215028-10 20 m...
Page 88
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION To Advantage Workstation if Hispeed connection is required TIO Console Rear HOST COMPUTER REAR PANEL ETHERNET PORTS A SWITCH HUB B HOSPITAL C GANTRY D BACKUP USB PORTS...
Together, those individuals then complete a site assessment to gauge what tasks are needed to fulfill the connection. Anyone can contact the GE Connectivity team at 800.321.7937, Option #3, with questions. Customer Broad-Band Responsibilities Provide GE Healthcare Installation Project Manager with an accurate site address, telephone number, contact name, and e-mail address for the: •...
Page 90
XCEL NSTALLATION • IT Contact Complete an equipment assessment with GE Healthcare Connectivity team to determine site readiness for broad-band • Contact your Installation Project Manager, for the name of the zone Broad-Band Specialist Work with the Customer Champion to complete any identified infrastructure changes...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 10.0 Radiation Protection NOTICE Scanner-room shielding requirements should be reviewed by a qualified radiological health physicist taking into consideration: • Scatter radiation levels within the scanning room (see...
Page 92
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION HEAD PHANTOM ISO– Contour Lev els: 0.33, 0.65, 1.3 and 2.6 µGy/Scan Technique: 140 kV 100mA 1 Sec 4 x 5.00mm 0.33 0.65 0.65 0.33 50cm 50cm HEAD PHANTOM ISO–...
Page 93
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION BODY SCATTER PHANTOM ISO– Contour Lev els: 0.65, 1.3, 2.6 and 5.2 µGy/Scan Technique: 140 kV 100mA 1 Sec 4 x 5.00mm 0.65 0.65 50cm 50cm BODY SCATTER PHANTOM ISO–...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure 4-24 Fluoro Stand Position Figure 4-25 Scatter Plot of Fluoro - Body Page 94 Section 10.0 - Radiation Protection...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure 4-26 Scatter Plot of Fluoro - Head Chapter 4 - Room Planning Page 95...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 11.0 Patient Environment The patient environment is defined as the following picture. Only Scanning Gantry, Patient Table components and the following options can be placed in this area.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Chapter 5 Environmental Conditions Ratings and duty cycles of CT subsystems apply if site environment meets the standards of this section. Maintain environmental conditions listed below at all times – including, for example, overnight, weekends and holidays.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Humidity (Scan Room & Control Room) Maximum allowable non-condensing relative humity: Minimum allowable non-condensing relative humity: Maximum allowable relative humidity rate change: 5% per hour Other Guidelines •...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 2.0 Cooling Requirement Table 5-1 to assist in cooling requirements planning. Over half the cooling used by your scanner is required for gantry operation. Locate a wall air-conditioning vent at floor level beside and behind gantry to meet both gantry cooling needs and provide patient comfort.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 4.0 Electro-Magnetic Interference (EMI) Note: If power sub-stations exist under or above the scan room, or near the control room, consider EMI testing to determine if your proposed room meets the published acceptable EMI room limits. This also includes high voltage lines under the scan or control room floor.
XCEL NSTALLATION EMI Reduction If fields of excessive EMI are known or suspected to be present, consult GE Medical Systems Sales & Service for recommendations. Consider the following if you attempt to reduce EMI: • External field strength decreases rapidly with distance from source of magnetic field.
Patient Table Gantry Camera (not GE) (Not GE Supplied) Counter w/sink and Base Cabinets Note: Drawing is not to scale Figure 5-1 Sample Room Layout, showing approximate EMI requirements Section 5.0 System Component Noise Levels Maximum Gantry Audible Noise Level The maximum ambient noise levels is produced by the gantry during a CT scan acquisition.
134 (652) floor using angle brackets Edge/Excel: monitors 397 (180) Notes: 1.) Use the GE Supplied mounting hardware ONLY IF APPROVED by qualified personnel. [See statements in 8.1 - Table and Gantry Mounting Requirements, on page 84.] 2.) Seismic angle brackets are included and shipped with the PDU..
Page 104
97 (44) 51 x 24 Workspace (part (1300 x 620) 5168666-3) Notes: 1.) Use the GE Supplied mounting hardware ONLY IF APPROVED by qualified personnel. [See statements in 8.1 - Table and Gantry Mounting Requirements, on page 84.] 2.) Seismic angle brackets are included and shipped with the PDU..
GE minimum load requirement and torque specification. Note: If installing the GE BS scanner on a floor type other than a 4 inch concrete floor, all structural specifications in this document must be reviewed and met.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure 6-1 Typical Floor Anchor, Gantry and Table Page 106 Section 2.0 - Mounting Data, Including Seismic...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 40.1" (1018) 81" (2057) 6-11/16" (170) Anchor Anchor Anchor Anchor FLOOR 11-7/8" (302.2) 34.75" 34.75" (878) (878) 24/13-16" (630) FRONT SIDE RIGHT SIDE Figure 6-2 Gantry Anchor...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION These two locations, leveling only No Anchors NOTE: 12.13 DIMENSIONS ARE IN (308.1) Z INCHES (MILLIMETERS) CENTER OF GRAVITY CENTER OF GRAVITY IS WITH 450 LB (205 KG) PATIENT FULLY EXTENDED 96.21...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 4461 (14ft. 7 5/8in.) 400 CRADLE EXTENDER (1ft. 3 3/4in.) NOTE CENTER OF GRAVITY IS WITH 227KG PATIENT FULLY EXTENDED ANCHOR ANCHOR (1ft. 2 7/8in.) (2ft. 9 5/8in.) 1979 (6ft.
Page 110
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 13.8 (350) (235) 14.2 (360) MINIMUM AIR FLOW CLEARANCE SEISMIC MOUNTING HOLES NOTES: SEISMIC FLOOR MOUNTING HOLES DIMENSIONS ARE IN INCHES (MILLIMETERS). (not to scale; see note) INDICATES CENTER OF GRAVITY Current PDU Seismic Bracket has holes alreadly drilled.
Page 111
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure 6-7 FWS Assembly (5168666-3) Chapter 6 - Floor Loading and Weights Page 111...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure 6-8 GOC4/LCGOC/AIO Operator Console Page 112 Section 2.0 - Mounting Data, Including Seismic...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure 6-9 TIO and NIO16 Console Seismic Mounting Hole Position Chapter 6 - Floor Loading and Weights Page 113...
Page 114
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Page 114 Section 2.0 - Mounting Data, Including Seismic...
1.2.2 Tilt Bed Truck If a tilt bed delivery truck is used, a GE representative shall supervise the delivery of the CT scanner to ensure the system is safely delivered without damage. To avoid damaging the table and gantry, the representative shall direct the driver to attach strapping to the lowest point (not the wheels) of each dolly.
The CT gantry assemblies shall not be lifted by their dollies. The CT gantry assemblies shall not be transported across any surface by any means other than the dollies provided by GE. The CT gantry assemblies have no lifting points on them and are not designed to be lifted by any special rigging attached to the gantry assemblies themselves.
The components ship attached to special lifting skids with lifting instruction for riggers. Floor Protection GE recommends floor protection along the delivery path from the dock/receiving area to scan room. Un-Loading and Un-packing the System Retain the packaging surrounding the following components: •...
Customers may purchase dollies (B7850LD) for shipments outside of the United States. After removing the system from the crates, DO NOT return dollies shipped outside of the US to GE Healthcare in Milwaukee, WI, USA. Instead, forward them to the local GE office or warehouse.Zero...
(B7850GD) to be used at the customer site. After the system has been removed from the crates, dollies shipped with international shipments only are not to be shipped back to GE in Milwaukee, WI, USA, but to be retained to the local GE office or warehouse.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 5.0 Table Considerations HP-Power Table The table is shipped with 2 crates. The mainbody of table is put in crate without dollies. Bottom Cover and accessaries are shipped in another crate.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure 7-2 Console packing True-In-One Console: The console is shipped without the keyboard table installed. The keyboard table is shipped with the console. The dimensions of the console alone (as shipped) are 740mm (29 in.) deep, 470mm (19 in.) wide, and 640mm (25 in.) high.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 8.0 Storage Requirements Short Term Storage (Less than 6 months) If the CT system is to be stored before installation, store in a temperature and humidity controlled warehouse.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION 20-60% Figure 7-3 Package Symbols (Storage) Section 9.0 Extreme Temperature Transportation and Deliveries NOTICE Failure to adhere to Extreme Temperature Transportation and Delivery requirements will likely result in equipment damage.
NEVER be installed in a construction site. Any site with unfinished floors, walls or ceilings is considered a construction site, and is not suitable for system installation. NOTICE The act of installing a GE CT scanner in a construction (i.e., unfinished) site will likely result in the following adverse effects: •...
NOTICE Never lift the gantry with a forklift. Lifting the gantry requires engineering approval for each occurrence. Your GE PMI should contact CT Engineering for all special lifting requirements, as unauthorized gantry lifting can cause gantry bearing damage. 11.3...
Page 126
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Page 126 Section 11.0 - Handling Requirements...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Chapter 8 Power Requirements Section 1.0 Introduction The power distribution unit (PDU) supplied with the system transforms and distributes power to all system components. The PDU is the only power entry point required to operate system.
PDU. It must be located within 10 m (32 ft.) of the PDU, dedicate to CT system, visible to PDU service personnel, and must have lockout /tagout provisions. Rating BrightSpeed Elite (16 slice), Edge (8 slice): 90kVA BrightSpeed Excel (4 slice): 75 kVA is standard rating, 90kVA is an optional rating.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Regulation Total load regulation as measured at the PDU input terminals must not exceed 6%. The capacity of the facility transformer and size & length of feeder wires directly affect the load regulation presented to the system.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 3.0 Recommended Power Distribution System A dedicated feeder run from the facility main isolation transformer is recommended to power the BrightSpeed CT scanner. If the scanner must be powered from an existing distribution transformer and secondary feeder, such as the equipment distribution panel of an X-ray department, installation with other X-Ray equipment that use rapid film changers should be avoided.
Page 131
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION FEEDER MINIMUM FEEDER WIRE SIZE, AWG OR MCM (SQ. MM)/ VAC LENGTH (MDA TO A1) 200 VAC 220 VAC 240 VAC 380 VAC 400 VAC 420 VAC 440 VAC 460 VAC 480 VAC...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 4.0 Ground System The BrightSpeed CT Scanner has been designed to use an equal potential grounding system. The required ground system is shown in Figure 8-1. There are three primary grounding points: •...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Chapter 9 Interconnection Data Section 1.0 Introduction Figure 9-5 shows interconnection runs for a 50/60 Hz system. Table 9-1 shows component designators for supplied equipment and options and wall power outlets.
Section 3.0 Interconnect Runs, Wiring and Cables GEMS Supplied (Optional, Short Run) LENGTH, UL CABLE INFORMATION ACTUAL (USABLE) PULL SIZE PART # DESCRIPTION MM (INCHES) 2343529-2 HVDC, PDU to Gantry 2587 FT4 + & - 350VDC 90 19 (.751) (2) 4 22 (0.87) Dia (20) (6.1)
Page 135
(19.3) 20.7 2117848-7 Fiber Optic, Gantry to OC N/A 10 (0.39) Dia (60) (18.3) 2343529-2 Signal, Gantry to Table FT-4 25 22 Table 9-3 GE Healthcare Supplied Cables for GOC or TIO (Standard Run) (2281840-5)- UL Information 9 – Interconnects...
Page 136
N/A 10 (.39) Dia (60) (18.3) 2333151 Signal, Gantry to Table FT-4 25 22 Table 9-4 GE Healthcare Supplied Cables for NIO16 Console (Standard Run) (2281840-14)- UL Information Note: For short cable kits GEHW Cat# is B71022RT, WSO Cat# is B7580JY...
GEMS Supplied (Freedom Workspace Table Extended Cables Kit) Extended Cables Kit (5160577) is used for FWS: DESCRIPTION QUANTITY CONNECT TO PART NUMBER LENGTH DVI-A HD15 Video Cable Monitor 5160573 181.10+/-3.94 4600+/-100 DVI-A HD15 Video Cable Monitor 5160573-2 181.10+/-3.94 4600+/-100 USB Extension Cable Trackball 5160574 118.11+/-3.94...
Page 138
5432953-3 Power Cable, Display monitor to Monitor NIO AC Box, IEC C14 to C13 Connectors 3050 50 120 1.97 5432953-4 Power Cable, Scan monitor to NIO Monitor AC Box, IEC C14 to C13 Connectors Table 9-7 GE Healthcare Supplied NIO16 Console Cables...
Ceiling Item#16 Console Monitors 2403438-4 SCIM Trackball Monitor Scan Display Keyboard Mouse In room Monitor Signal Monitor Monitor DASM Option Cables Signal Respiratory Hospital Network Barcode Monitor Power Reader InSite Modem Cords Signal Power Gantry RUN # 053 To A1 Power Power Panel Host Console Power...
Console Monitors Ceiling Item #16 2403438-4 SCIM Trackball Scan Display Monitor Keyboard Mouse Monitor Cables Media Tower 2256482 In room Monitor Hospital Network Power Cords InSite Modem Barcode Reader MOD Tower 2142225 Signal InSite Modem Power Monitor Signal Power Respiratory Video Monitor Signal...
Keyboard Console Monitors Ceiling Item #16 2403438-4 Trackball Media Tower Scan Display Monitor Mouse Barcode Reader Power Cable In room Monitor InSite Modem 5315013-4 GSCB EXT HDD GSCB Cable Hospital Net Signal 5404262 Power Monitor Signal Power Respiratory Video Monitor Signal USB2.0 Splitter...
GEMS Supplied (Optional, Long Run) LENGTH, UL CABLE INFORMATION ACTUAL (USABLE) PULL SIZE PART # DESCRIPTION MM (INCHES) 19.3 2343529 HVDC, PDU to Gantry 2587 FT4 + & - 350VDC 90 19 (.751) (2) 4 22 (0.87) Dia (55) (16.76) (1) 8 051 62.5 2343530...
Page 144
2373436-2 Signal (LAN), Gantry to OC 1900 <30VDC 5.9 (.234) 15 (0.59) Dia (81) (24.86) 24.3 2117848-2 Fiber Optic, Gantry to OC 10 (0.39) Dia (75) (22.86) Table 9-9 GE Healthcare Supplied Cables for GOC or TIO (Optional, Long Run) (2281840-4)- UL Information...
Page 145
24.3 5432019 Fiber Optic, Gantry to OC 10 (.39) Dia (75) (22.86) Table 9-10 GE Healthcare Supplied Cables for NIO16 Console (Optional, Long Run) (2281840-13)- UL Information Note: For long cable kits GEHW Cat# is B70992RT, WSO Cat# is B7580JZ...
GEMS Supplied (Cables of Options) LENGTH, UL CABLE INFORMATION ACTUAL (USABLE) PULL SIZE PART # DESCRIPTION MM (INCHES) 22.9 2403438-3 5 BNC MALE TO HD 15 1Vp-p MALE 75 FEET (0.358) 21.2 2213219 POWER CABLE FOR LCD- 120VAC CONSOLE TO LCD (0.366) 21.5 5116219...
Page 147
LENGTH, UL CABLE INFORMATION ACTUAL (USABLE) PULL SIZE PART # DESCRIPTION MM (INCHES) 100 30.5 5199717 GANTRY TO RPM UNIT 2464 FT4 <30VDC 37(1.45) Dia (0.26) Table 9-11 GEMS Supplied Cables for Options - UL Information...
Contractor (Customer) Supplied CUSTOMER DESCRIPTION CABLES SUPPLIED PLUG PULLING WIRE & CABLE INSTALLED WIRING DIMENSIONS PIGTAILS FT. (M.) SIZE AWG PART NO LENGTH DIA. FROM FROM FT. (M.) IN (MM) RUN NO. 1 FROM PRIMARY POWER SOURCE TO FACILITY DISCONNECT (POWER SOURCE - A1) Maximum Run Length * POWER 3 (1)
1) Used for remote diagnostics - Option 2) Refer to the appropriate Pre-installation / Installation documents for the Laser Camera TELEPHONE 3) Category 5 cable. Use one of the following patch cords: SYSTEM CAT Num GE Part Num Length (see Note 1) K9000WB 2215028-10 20 m...
LITE XCEL NSTALLATION Section 4.0 Contractor Supplied Components REFERENCE ASSOCIATED MATERIAL/LABOR SUPPLIED BY USA VENDOR / CAT NO. GE EQUIPMENT CUSTOMER CONTRACTOR CATALOG Fusible Disconnect Recommended:* 3 Pole, 380V - 480V, Combination breaker and Magnetic with magnetic contactor. Includes control •...
Page 151
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION ITEM NUMBER QTY FRU CODE DESCRIPTION/NAME U8009FF FUSE 3.2A U8008FF FUSE 2.0A U8006FF FUSE 1.0A Table 9-14 FUSE KIT BS 90KVA (2385412-2 BOM, rev 2) (Continued) ITEM...
Primary Power Disconnect Requires LOTO compatible disconnect to install this system. If a UPS is required, a GE Disconnect is strongly recommended for safe operation. The GE disconnect and UPS are designed to work together. Figure 9-7 Primary Power Disconnect (A1)
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure 9-8 Primary Power Disconnect (A1) - Fusible Disconnect and Magnetic Contactor Page 154 Section 7.0 - Typical Customer Supplied Wiring...
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Scan Room Warning Light & Door Interlock Door Switch EXP_INTLK PGND Figure 9-9 Typical TS6 Warning Light & Door Interlock Connections If not using a door switch, add a jumper.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Section 8.0 Recommended Power Distribution System (For Europe) Figure 9-12 Power Distribution Interconnect Box (for Europe) 1/2 Page 156 Section 8.0 - Recommended Power Distribution System (For Europe)
Page 157
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure 9-13 Power Distribution Interconnect Box (for Europe) 2/2 Chapter 9 - Interconnection Data Page 157...
Page 158
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Page 158 Section 8.0 - Recommended Power Distribution System (For Europe)
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Appendix A Alternate Cover Removal Options Section 1.0 Alternate Cover Removal Options Overview The room dimensions and clearance dimensions shown in this manual assume a room configuration in which the front and rear gantry covers are removed and stored straight back/ forward from the gantry.
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED Rear Cover Removal Rather than storing the rear cover straight back from the gantry, the cover can be moved and stored on the right or left side or angled if there is space available while still maintaining service access to the gantry.
Page 161
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure A-1 Standard Service Access Appendix A – Alternate Cover Removal Options Page 161...
Page 162
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED Figure A-2 Front Cover Removal and Storage to Left Side Page 162 Section 1.0 - Alternate Cover Removal Options...
Page 163
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure A-3 Front Cover Removal and Storage to Right Side Appendix A – Alternate Cover Removal Options Page 163...
Page 164
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED Figure A-4 Front Cover Removal with Table Up, Storage to Left Side Page 164 Section 1.0 - Alternate Cover Removal Options...
Page 165
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure A-5 Front Cover Removal with Table Up, Storage to Right Side Appendix A – Alternate Cover Removal Options Page 165...
Page 166
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED Figure A-6 Rear Cover Removal and Storage Straight Back Page 166 Section 1.0 - Alternate Cover Removal Options...
Page 167
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Figure A-7 Rear Cover Removal and Storage to Left or Right Side Appendix A – Alternate Cover Removal Options Page 167...
Page 168
GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED Figure A-8 Rear Cover, Gantry Angled, Storage in Corner Page 168 Section 1.0 - Alternate Cover Removal Options...
Need help?
Do you have a question about the BrightSpeed Elite and is the answer not in the manual?
Questions and answers
I need service manual for ct brighspeed ge Thanks
The service manual for the GE BrightSpeed Elite CT can be found in the GE Healthcare documentation. You may need to contact your local GE Medical Systems Sales representative or visit the GE Healthcare website for a complete list of system options and manuals.
This answer is automatically generated