Installation

2.11 Three-phase Gear Motors Connection Diagram

CAUTION
Refer to the Operating Instructions for VLT
terminals.
®
Do not connect the VLT
OneGearDrive directly to the power supply.
Illustration 2.7 shows the connection power plug for VLT
thermistors.
Illustration 2.7 Three-phase Gear Motor Connections
Description
Motor winding
Protective Earth
Temperature protection
1)
KTY 84-130
Table 2.7 Three-phase Gear Motor Connections
®
1) When connected to VLT
AutomationDrive FC 302 and VLT
information about parameter setting and programming, refer to the corresponding operating instructions.
T1
KTY 84-130
T2
Table 2.8 Connections T1 and T2
1) Only if connected
®
VLT
OneGearDrive Operating Instructions
®
AutomationDrive FC 302 and VLT
®
OneGearDrive Hygienic DA09LA10 in Y-connection with
V1
W1
U1
Inverter output
Pin
U
1
V
3
W
4
PE
2
T1
A
T2
B
®
Decentral Drive FCD 302, use analog input terminal 54, KTY sensor 1. For
®
VLT
AutomationDrive FC 302
1)
®
MG75C302 - VLT
is a registered Danfoss trademark
®
Decentral Drive FCD 302 to connect the
V
D
W
3
C
4
2
B
T1
1
A
T2
U
Typical cross section
Maximum cross section
AWG 16/1.5 mm
2
AWG 14/2.5 mm
2
AWG 16/1.5 mm
AWG 14/2.5 mm
2
AWG 20/0.75 mm
AWG 16/1.5 mm
®
VLT
Decentral Drive FCD 302
KTY Sensor 1
Analog Input 54
2
2
2
2
1)
13
2