Chapter 6: Optional Interface

Optional serial interface

Use a thin flat-blade screwdriver or some other similar object to change DIP
switch settings on the optional serial interface board.
The following table shows all the possible settings for the DIP switches. All
switch settings, except for 1-7 and 1-8, are ON when the printer is shipped from
the factory.
Switch
1
2
3
4
5
6
7
8
ON
1
OFF
Parameter
Baud Rate
Data Length
Parity Check
Parity Selection
Handshake
Serial I/F Pin 6 Reset Signal
Serial I/F Pin 25 Reset Signal
Baud Rate
2400BPS
4800BPS
9600BPS
19200BPS
2
3
4
5
6
7
Switch 1
OFF
ON
ON
OFF
8
ON
See table below
8 bits
Disabled
Odd
DTR/DSR
Active
Active
Switch 2
OFF
OFF
ON
ON
21
OFF
7 bits
Enabled
Even
XON/XOFF
Inactive
Inactive