1-
Set horizontal tab stop every n columns
Mode
ASCII
Decimal
Hexadecimal
std.
<ESC> "e" <0>
//
27 101
0
)1
IB
65 00
r?
Cancels all current horizontal tab stops and sets new tab stops every
n columns, where n is between 1 and 127.
Reset all tab stops
Mode I
ASCII
Decimal
Hexadecimal
1
I IBM
<ESC> '"R"
27 82
IB
52
Resets the horizontal tab stops to their power-up values in which a
tab stop is set every 8 column starting at column 9. Also clears all
vertical tab stops.
Horizontal tab
Mode
ASCII
Decimal
Hexadecimal
Both
<HT>
9
09
Moves the print position to the next horizontal tab stop. Ignored if
there is no next horizontal tab stop in the current line. Note that when
underlining is selected, spaces skipped by horizontal tabulation are
not under]ined.
Relative horizontal tab
Mode
ASCII
Decimal
Hexadecimal
Std.
<ESC> "'/"
1![
,,~
27 92 H/ //2
IB
5C ///
//2
Moves the print position right or left a specified distance. Ignored if
the resulting position is beyond the rightor left margin. The formulas
for the distance and direction are as follows:
If 122 is between ()and 63, the print head moves right by (~?l+ 112 x
256) dots.
If you want to move the print head to the left, }?land )12are obtained
by subtracting the value from 65536, and dividing the result into
high and low bytes.