Installation
EN
Connecting the cooking zones when the cooktop is
installed rotated by 180°
5
Fig. 5.20
Cooking zone connection in 180° installation
[1]
Cooktop
[2]
Rear cooking zone (zone 2)
[3]
Front cooking zone (zone 1)
[4]
Rear cooking zone control knob (zone 2)
[5]
Front cooking zone control knob (zone 1)
Connect the connection on the back of the left control
X
X
knob [5] to the "zone 1" connection on the back of the
cooktop [1].
Connect the connection on the back of the right
X
X
control knob [4] to the "zone 2" connection on the
back of the cooktop [1].
Using the configuration menu, set the correct
X
X
allocation of the cooking zones in the control
knob display (see Configuration menu, 0° or 180°
installation).
Connecting the automatic extraction system
Connect the cooktop extractor to the cooktop using the
X
X
connector provided for the automatic extraction system.

5.5.6 Establishing the power connection

Observe all safety and warning information (see the
X
X
Safety chapter).
Observe all national and regional laws and regulations
X
X
as well as the supplementary regulations of the local
utility companies.
INFO The power connection may only be established by
certified specialists. The specialist also assumes
responsibility for the proper installation and
commissioning.
20
1
2
3
4
INFO This appliance is intended to be operated on
a supply network with an impedance Zmax at
the transfer point (mains connection) of 0.104
ohms maximum. The user is to ensure that the
appliance is only operated on a mains supply
network which meets this requirement. If
necessary, ask the local energy supply company
about the system impedance.
The power supply line to be used (pre-assembled) must
be at least Type SiHF.
(see table Fuse protection and minimum cross-section.
Connection
Fuse protection
1-phase connection
1 x 25 A
2-phase connection
2 x 16 A
Tab. 5.4
Fuse protection and minimum cross-section
If the connection cable has been damaged this must
Q
Q
be replaced. This may only be done by an authorised
member of the After Sales Service team.
Switch off the main switch/automatic circuit breaker
X
X
before connecting the cooktop.
Secure the main switch/automatic circuit breaker
X
X
against being switched back on without permission.
Make sure the power to the appliance is disconnected.
X
X
Only connect the cooktop using a permanent
X
X
connection to a power supply cable.
1
2
L1
L2
220 - 240 V~
220 - 240 V~
Fig. 5.21
Connection diagram 2-phase
1
2
L1
220 - 240 V~
Fig. 5.22
Connection diagram 1-phase
Check that installation has been carried out correctly.
X
X
Switch on the main switch/automatic circuit breaker.
X
X
Put the cooktop into operation (see the Operation
X
X
chapter).
Check that all the functions are working correctly.
X
X
Minimum
cross-section
²
2.5 mm
²
2.5 mm
3
N
PE
3
N
PE