Electrical Limit Switches - Parker LCB Series Installation, Commissioning, Maintenance And Repair

Electromechanical automation compact linear actuator
Hide thumbs Also See for LCB Series:
Table of Contents

Advertisement

Parker EME
6.2

Electrical limit switches

LCB040
LCB060
Connection diagram LCB040 and LCB060
1: PNP normally closed contact
2 -3: Load
Technical data: limit switches LCB040 and LCB060
Switching distance
Switch hysteresis
Repeatability
Temperature drift
Ambient temperature
Protection class
Cable Length
192-510014 N04 March 2010
Electrical characteristics
2 mm / 4 mm ± 10 %
Rated Voltage
> 1 % ...< 15 %
Voltage range
0.01 mm
Supply current
< 10 %
Maximum load current
-25 °C - +70 °C
Residual voltage
IP67
Switching frequency
6 m
Connecting cables
Accessories
60
51
12
1
10
6
40
4,5
6
20
69
5,5
80
40
br
1
bn
sw
A 2
bk
bl
3
bu
24 VDC
10...35 VDC
< 15 mA
300 mA
< 2.5 VDC
2 kHz
3 x 0.25 mm
4,5
4,5
2
39