Conditions of utilization ....................10 Device assignment This manual is valid for the following devices: Linear actuator: LCB040 Linear actuator: LCB060 Type specification plate Type specification plate (example) Parker Hannifin GmbH Identification No.: 312707 0002 Electromechanical Automation Art. No.: LCB060MG00600SRN Robert-Bosch-Straße 22 Type:...
Introduction Compact Linear Actuator - LCB Safety instructions In this chapter you can read about: General hazards ........................ 6 Intended use ........................6 Identifying Residual Dangers and Hazardous Areas ............6 Working safely ........................7 Safety Instructions for the Company Using the System ............7 Safety Instructions for Operating Personnel ...............
Components and accessories are designed especially for this product. When purchasing spare and wearing parts, use only original Parker parts. We note here explicitly that we are unable to check or release spare parts or accessories that were not provided by us.
Introduction Compact Linear Actuator - LCB changes in the required design properties in some circumstances, which in turn could negatively effect the active and/or passive operating safety of the product. The manufacturer is unable to accept any liability for damage caused by using non- original parts and accessories.
Introduction Parker EME 1.5.1. Special notes on transport Special notes on transport Use only transport equipment with sufficient lifting capacity. When using ropes, make certain they are not twisted or knotted. If you are using more than one rope, all the ropes should be equally taut.
Introduction Compact Linear Actuator - LCB Warranty conditions User Conversions and Changes are Not Permitted The linear actuator must not be changed in its design or in terms of safety without our approval. Any change as defined here made by the user excludes any liability on our part.
Fitting / mounting ......................12 The linear module is furnished completely mounted and mechanically ready-to- operate. If no Parker drive is provided, attach your motor-gearbox combination according to the instructions of the respective supplier. The technical data must be respected.
Commissioning Compact Linear Actuator - LCB LCB060 10000,0 10000.0 1000,0 1000.0 100,0 100.0 10,0 10.0 1000 1500 2000 2500 3000 3500 4000 Stützabstand SA [mm] Distance between mountings SA [mm] (1): Maximum permitted deflection Fitting / mounting 2.2.1. Installation of a single actuator Danger when transporting long actuators.
Commissioning Parker EME 2.2.2. Installation of a double-axis actuator Taking the linear actuator out of the shipping crate. Place it on the leveled holding points (water level, leveling device). Fix the module (LCB mounting methods) Place second actuator and fix slightly.
Commissioning Compact Linear Actuator - LCB The sliding carriages of the two linear actuators must stand on the same position P (Recommendation: Push both actuators to the same stop). Place half-coupling for small shaft diameter on the free shaft ends with distance A ...
Page 15
Commissioning Parker EME Drawing without lateral cover Unit LCB040 LCB060 Drive Option (PTN060) (SMH60) (SY56) (PTN080) (SMH100) (SY107) Distance between flange surface [mm] 13.5 of the coupling housing and the coupling Tightening torque of clamping [Nm] 10.5 screws Distance between flange surface...
Repair jobs must only be performed by qualified specialists or employees of Parker. Only qualified expert personnel is permitted to perform works on the linear actuator. All the applicable regulations and provisions must be heeded (IEC, EN, national accident prevention regulations etc.).
Parker EME Maintenance Maintenance schedule Please take special care during all maintenance and repair that the guiding surface Note remains intact! WHEN WHAT ACTION Check free movement of the sliding carriage by manually After commissioning Sliding carriage moving the sliding carriage. (Check) (see on page 17) Check sliding carriage play and replace sliding blocks if necessary.
Page 18
and service Compact Linear Actuator - LCB Maintenance Check sliding play (LCB) Use a feeler gauge stock to determine the current wear as shown in the photograph on the left. Lift sliding carriage plate for measurement. Exchange sliding block (LCB) The sliding block is a wearing part.
Page 19
Parker EME Maintenance Unscrew only the two upper screws of the cover at the deflection station (unscrew for about 1 3mm, not more as they do not only fix the cover but also the deflection station itself). Remove cover in upwards direction Unscrew the two fixing screws at all four sliding blocks entirely and remove sliding blocks.
and service Compact Linear Actuator - LCB Maintenance Checking / exchanging / tensioning toothed belt Causes for abnormal toothed belt wear A certain sign of wear may have different causes so that it is not always possible, to determine the exact cause.
Parker EME Maintenance 3.5.2. Dismantling the toothed belt We recommend to remove the covers at the drive station and the deflection station before dismantling the toothed belt ("Remove covers (see on page 18)). Unscrew tensioning bracket on both sides of the sliding carriage and remove from ...
Page 22
(specific mass of belt, freely oscillating length of belt) and the oscillating frequency of the belt. The belt tension measuring device can be purchased at Parker (Part-No. 037-000202). An operating manual with a description of the measuring procedure comes with the device.
Index Parker EME 4. Index Attachment of Motor or Gearbox - 14 Type specification plate - 4 Check free movement of the sliding carriage - Warranty conditions - 10 Working safely - 7 Checking / exchanging / tensioning toothed belt...