Parker LCB Series Mounting Instructions
Parker LCB Series Mounting Instructions

Parker LCB Series Mounting Instructions

Compact linear actuator

Advertisement

Quick Links

Compact Linear Actuator - LCB
Mounting instructions
LCB Manual - Installation, Commissioning, Maintenance and
Repair
LCB - Compact Linear Actuator
Technische Änderungen vorbehalten.
Daten entsprechen dem technischen Stand zum Zeitpunkt der Drucklegung.
Electromechanical Automation
Sizes LCB040 and LCB060
16.11.16 16:39
DOC-0009-03
DOC-0009-03
192-510014 N06
192-510014 N06 April 2013
April 2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LCB Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Parker LCB Series

  • Page 1 Compact Linear Actuator - LCB Electromechanical Automation Mounting instructions LCB Manual - Installation, Commissioning, Maintenance and Repair LCB - Compact Linear Actuator DOC-0009-03 DOC-0009-03 192-510014 N06 April 2013 Sizes LCB040 and LCB060 Technische Änderungen vorbehalten. 16.11.16 16:39 192-510014 N06 April 2013 Daten entsprechen dem technischen Stand zum Zeitpunkt der Drucklegung.
  • Page 2 Introduction Linear Actuator - LCB Compact ____________________________ Production site: Parker Hannifin Manufacturing Germany GmbH & Co. KG Electromechanical & Drives Division [EME] Robert-Bosch-Strasse 22 77656 Offenburg (Germany) Tel.: + 49 (0781) 509-0 Fax: + 49 (0781) 509-98176 Internet: www.parker.com/eme E-mail: sales.automation@parker.com Italy: Parker Hannifin Manufacturing Srl •...
  • Page 3: Table Of Contents

    Introduction Parker EME Inhalt 1. Introduction ..................... 4 Device assignment .................. 4 Type specification plate ................4 Mounting explanation ................5 Safety instructions ................... 6 1.4.1. General hazards ....................6 1.4.2. Intended use ....................... 6 1.4.3. Identifying Residual Dangers and Hazardous Areas ........6 1.4.4.
  • Page 4: Introduction

    Conditions of utilization ....................10 Device assignment This manual is valid for the following devices: Linear actuator: LCB040 Linear actuator: LCB060 Type specification plate Type specification plate (example) Parker Hannifin GmbH Identification No.: 312707 0002 Electromechanical Automation Art. No.: LCB060MG00600SRN Robert-Bosch-Straße 22 Type:...
  • Page 5: Mounting Explanation

    Introduction Parker EME Mounting explanation 192-510014 N06 April 2013...
  • Page 6: Safety Instructions

    Introduction Compact Linear Actuator - LCB Safety instructions In this chapter you can read about: General hazards ........................ 6 Intended use ........................6 Identifying Residual Dangers and Hazardous Areas ............6 Working safely ........................7 Safety Instructions for the Company Using the System ............7 Safety Instructions for Operating Personnel ...............
  • Page 7: Working Safely

    Components and accessories are designed especially for this product. When purchasing spare and wearing parts, use only original Parker parts. We note here explicitly that we are unable to check or release spare parts or accessories that were not provided by us.
  • Page 8: Packaging, Storage, Transport

    Introduction Compact Linear Actuator - LCB changes in the required design properties in some circumstances, which in turn could negatively effect the active and/or passive operating safety of the product. The manufacturer is unable to accept any liability for damage caused by using non- original parts and accessories.
  • Page 9: Special Notes On Transport

    Introduction Parker EME 1.5.1. Special notes on transport Special notes on transport Use only transport equipment with sufficient lifting capacity. When using ropes, make certain they are not twisted or knotted. If you are using more than one rope, all the ropes should be equally taut.
  • Page 10: Warranty Conditions

    Introduction Compact Linear Actuator - LCB Warranty conditions User Conversions and Changes are Not Permitted The linear actuator must not be changed in its design or in terms of safety without our approval. Any change as defined here made by the user excludes any liability on our part.
  • Page 11: Commissioning

    Fitting / mounting ......................12 The linear module is furnished completely mounted and mechanically ready-to- operate. If no Parker drive is provided, attach your motor-gearbox combination according to the instructions of the respective supplier. The technical data must be respected.
  • Page 12: Fitting / Mounting

    Commissioning Compact Linear Actuator - LCB LCB060 10000,0 10000.0 1000,0 1000.0 100,0 100.0 10,0 10.0 1000 1500 2000 2500 3000 3500 4000 Stützabstand SA [mm] Distance between mountings SA [mm] (1): Maximum permitted deflection Fitting / mounting 2.2.1. Installation of a single actuator Danger when transporting long actuators.
  • Page 13: Installation Of A Double-Axis Actuator

    Commissioning Parker EME 2.2.2. Installation of a double-axis actuator Taking the linear actuator out of the shipping crate.  Place it on the leveled holding points (water level, leveling device).  Fix the module (LCB mounting methods)  Place second actuator and fix slightly.
  • Page 14: Setting The End Limits

    Commissioning Compact Linear Actuator - LCB The sliding carriages of the two linear actuators must stand on the same position  P (Recommendation: Push both actuators to the same stop). Place half-coupling for small shaft diameter on the free shaft ends with distance A ...
  • Page 15 Commissioning Parker EME Drawing without lateral cover Unit LCB040 LCB060 Drive Option (PTN060) (SMH60) (SY56) (PTN080) (SMH100) (SY107) Distance between flange surface [mm] 13.5 of the coupling housing and the coupling Tightening torque of clamping [Nm] 10.5 screws Distance between flange surface...
  • Page 16: Maintenance And Service

    Repair jobs must only be performed by qualified specialists or employees of Parker. Only qualified expert personnel is permitted to perform works on the linear actuator. All the applicable regulations and provisions must be heeded (IEC, EN, national accident prevention regulations etc.).
  • Page 17: Maintenance Schedule

    Parker EME Maintenance Maintenance schedule Please take special care during all maintenance and repair that the guiding surface Note remains intact! WHEN WHAT ACTION Check free movement of the sliding carriage by manually After commissioning Sliding carriage moving the sliding carriage. (Check) (see on page 17) Check sliding carriage play and replace sliding blocks if necessary.
  • Page 18 and service Compact Linear Actuator - LCB Maintenance Check sliding play (LCB) Use a feeler gauge stock to determine the current wear as shown in the photograph on the left. Lift sliding carriage plate for measurement. Exchange sliding block (LCB) The sliding block is a wearing part.
  • Page 19 Parker EME Maintenance Unscrew only the two upper screws of the cover at the deflection station (unscrew for about 1 3mm, not more as they do not only fix the cover but also the deflection station itself). Remove cover in upwards direction Unscrew the two fixing screws at all four sliding blocks entirely and remove sliding blocks.
  • Page 20: Checking / Exchanging / Tensioning Toothed Belt

    and service Compact Linear Actuator - LCB Maintenance Checking / exchanging / tensioning toothed belt Causes for abnormal toothed belt wear A certain sign of wear may have different causes so that it is not always possible, to determine the exact cause.
  • Page 21: Dismantling The Toothed Belt

    Parker EME Maintenance 3.5.2. Dismantling the toothed belt We recommend to remove the covers at the drive station and the deflection station before dismantling the toothed belt ("Remove covers (see on page 18)). Unscrew tensioning bracket on both sides of the sliding carriage and remove from ...
  • Page 22 (specific mass of belt, freely oscillating length of belt) and the oscillating frequency of the belt. The belt tension measuring device can be purchased at Parker (Part-No. 037-000202). An operating manual with a description of the measuring procedure comes with the device.
  • Page 23: Index

    Index Parker EME 4. Index Attachment of Motor or Gearbox - 14 Type specification plate - 4 Check free movement of the sliding carriage - Warranty conditions - 10 Working safely - 7 Checking / exchanging / tensioning toothed belt...
  • Page 24 Compact Linear Actuator - LCB 192-510014 N06 April 2013...

This manual is also suitable for:

Lcb040Lcb060

Table of Contents