Table 3-5 Standard Overload Curve Trip Times (In Seconds) - GE MULTILIN 269 MOTOR MANAGEMENT RELAY Series Instruction Manual

Table of Contents

Advertisement

Table 3-5 Standard Overload Curve Trip Times (in seconds)

Overload
Level
1
1.05
853
1.10
416
1.20
198
1.30
126
1.40
91
1.50
70
1.75
42
2.00
29
2.25
21
2.50
16
2.75
13
3.00
10
3.50
7
4.00
5
4.50
4
5.00
3
5.50
2
6.00
2
6.50
2
7.00
1
7.50
1
8.00
1
* - Factory preset value
GE Multilin Standard Curve Number
2
3
1707
2560
3414
833
1249
1666
397
596
253
380
182
273
140
210
84
127
58
87
43
64
33
49
26
39
21
32
15
23
11
17
9
13
7
10
5
8
4
7
4
6
3
5
3
4
2
3
4*
5
5975
7682
2916
3749
795
1391
1789
507
887
1141
364
637
820
280
490
630
169
296
381
116
203
262
86
150
193
66
116
149
53
92
43
76
30
54
23
40
18
31
14
25
11
20
9
17
8
14
7
12
6
10
5
9
3 SETUP AND USE
6
7
10243
12804
4999
6249
2385
2982
1521
1902
1093
1366
840
1050
508
636
349
436
258
322
199
249
119
159
198
98
131
163
69
92
52
69
40
54
32
43
26
35
22
29
18
24
16
21
13
18
11
15
8
115
87
67
54
43
36
30
27
22
19
3-53