Register 0Xe - Dac Register Read Back - Sundance Spas SMT370v2 User Manual

Table of Contents

Advertisement

Version 1.0
Register 0xE – DAC Register Read back.
Bit
number
Bit 31
Bit 30
Bit 29
Bit 28
Bit 27-0
By sending this control word, the FPGA reads back the DAC register from the AD9777. Once this
control word has been sent on CP3 of the 370, expect to receive 15 CommPort word in return on the
same link. They all start by 0xAD9777. The two last digits (LSBs) give the value of the DAC internal
register. The 370 starts by sending out register at address 0x0, and carries on up to register 0xd.
Example:
Let's consider that the following registers have been loaded into the DAC
Register0 = 0x00010203
Register1 = 0x01111213
Register2 = 0x02212223
Register3 = 0x03313233
Register4 = 0x04414243
After sending the word 0xE0000000, the SMT370 will get back in return the following
values:
0xAD977701,
0xAD977721, 0xAD977722, 0xAD977723, 0xAD977731, 0xAD977732, 0xAD977733, 0xAD977741,
0xAD977742, 0xAD977743.
This function gives the user a way to verify that the DAC has been loaded with the correct registers.
Page 36 of 44
0xAD977702,
0xAD977703,
Description
1
1
1
0
Not Used.
0xAD977711,
0xAD977712,
SMT370v2 User Manual
0xAD977713,

Advertisement

Table of Contents