Pipework Connections (Hot)
When a hot water cylinder or storage tank is used, ensure the pipework size from the
cold water storage to the hot water storage is of adequate size and a minimum of 28 mm.
The pump must be supplied with a dedicated feed direct from the hot water
cylinder or storage tank.
Ensure the pipework size from the hot water storage tank to the pump is of adequate
size and a minimum of 28 mm. The supply must be air free and connection to the
cylinder can be via an Essex flange, or by one of the methods shown in Fig. 7.
When the method of connection is to be made via the expansion pipe, the cold water
cistern should be at least 1.5 metres above the top of the hot water cylinder.
Most preferred
Existing
secondary
tappings
22 mm
Pipework Connections (Connection between pump and system outlets)
This should run as far as possible in 22 mm copper tube. Any bend requirements
should be achieved by hand drawing the tube or by use of the appropriate bend fittings.
Pipework should only be reduced to 15 mm copper if necessary when entering the
terminal fittings. By this method the maximum performance of the pump will be
maintained. All pipework should be securely clipped.
STEP 4 PUMP CONNECTIONS (Release and connection of push-in connectors)
WARNINGS:
Do not use stainless steel, chrome or nickel plated pipe with Stuart
Turner push-in plumbing connections.
Do not introduce solder flux into the joint or surrounding area as
connectors will be attacked and may fail.
All solder joints should be completed and flux residues removed
before final connection to push in connections, either on flexible hose
or pump head.
Do not allow contact with oil or cellulose based paints, paint thinners
or strippers, acid based descalents or aggressive cleaning agents.
Fig. 7
Essex
flange
28 mm
Surrey
flange
22 mm outlet
(As close to the cylinder as possible)
- 7 -
45°
Off expansion
pipe, off-set 45°,
28 mm pipework
Least
preferred
Off vertical
expansion
pipe 28 mm
pipework