Pump Connections - Stuart Turner Showermate Series Installation Instructions Manual

Shower booster pumps
Table of Contents

Advertisement

Pipework Connections (Cold)
The pump must be supplied with a dedicated feed direct from the cold water
storage tank.
The supply must be air free and connection of the feed pipe to the tank should be via a
tank connector, positioned at a slightly lower level (25 mm minimum) than the feed pipe to
the hot water cylinder.
Pipework Connections (Hot)
When a hot water cylinder or storage tank is used, ensure the pipework size from the
cold water storage to the hot water storage is of adequate size and a minimum of 22 mm.
The pump must be supplied with a dedicated feed direct from the hot water
cylinder or storage tank.
The supply must be air free and connection to the cylinder can be made by one of the
methods shown in Fig. 9.
When the method of connection is to be made via the expansion pipe, the cold water
storage cistern should be at least 1 metre above the top of the hot water cylinder.
Most
preferred
Off expansion
pipe with rising
28 mm offset
reducing to
22 mm pipework
to pump and
expansion pipe.
Pipework Connections (Connection between pump and system outlet)
This should run as far as possible in 22 mm copper tube. Pipework should only be
reduced to 15 mm copper at pump and if necessary when entering the terminal fittings.
By this method the maximum performance of the pump will be maintained.
STEP 3 PUMP CONNECTIONS (Release and connection of push-in connectors)
WARNINGS:
Do not use stainless steel, chrome or nickel plated pipe with Stuart
Turner push-in plumbing connections.
Do not introduce solder flux into the joint or surrounding area, as
plastics will be attacked and may fail.
All solder joints should be completed before final connection to push-
in connections, either on the flexible hose or the pump head. Flux
residues must be removed.
Off expansion
Off vertical
pipe with rising
expansion pipe
22 mm offset
with 22 mm
and 22 mm
pipework to
pipework to
pump.
pump.
Factory installed G ¾
secondary tapping
with 22 mm pipework
to pump.
or
Site installed G ¾
Essex Fange with
22 mm pipework to
pump.
- 6 -
Least
preferred
Warix Flange with
22 mm pipework to
pump.
Fig. 9