Replacing A Carbonator Pump Motor - Cornelius Energize6 Service Manual

Backroom soda chiller package
Table of Contents

Advertisement

Replacing a Carbon-
ator Pump Motor
© 2012, IMI Cornelius Inc.
Pressure
Sensors
To remove and replace a carbonator pump motor, perform the procedure in Table 17.
Step
1
Turn off the electrical supply to the unit.
2
Remove the cover using the procedure in "Removing the Unit Cover" on page 14.
Unplug the connector from the control box, making sure to remove any tie
wraps holding the wiring in place.
TIP: Once all tie wraps have been removed, tie a length of string to the
3
connector before pulling it out of the control board. Then pull the wiring out
of the unit and untie the string. Use the string to fish the new wiring back
through the unit to the control box.
4
Remove the ground wire from the chassis as shown in Figure 19 on page 22.
5
Remove the pump retaining collar, shown in Figure 25.
6
Remove the pump from the motor by pulling it away from the motor.
7
Install the new carbonator pump motor.
8
Replace the electrical connection from the recirculating pump to the control box.
Turn the water supply on and make sure the water bath level is up to the
9
notch in the overflow tube.
- 25 -
Energize6 Service Manual
Figure 24.
Retaining
Collar
Figure 25.
Table 17.
Action
Publication Number: 621058457SER