High Pressure Switch Replacement - Cornelius Energize6 Service Manual

Backroom soda chiller package
Table of Contents

Advertisement

H
P
IGH
RESSURE
© 2012, IMI Cornelius Inc.
S
R
WITCH
EPLACEMENT
Before replacing the high pressure switch, inspect the remote condenser for proper
air flow, any obstructions or a failed fan motor.
The high pressure switch, shown in Figure 38, is located at the left rear of the unit,
behind the access panel. The switch has a reset button. The reset button should be
pressed and the unit restarted before replacing the high pressure switch. If the
switch trips again, replace the switch by performing the procedure in Table 24.
Step
1
Turn off the electrical supply to the unit.
2
Remove the access panel from the rear of the unit.
Unplug the electrical connections from the high pressure switch to the con-
trol box. and remove any tie wraps holding the wiring.
3
TIP: Tie a length of string to the connector before pulling it out of the con-
trol board. Then pull the wiring out of the unit and untie the string. Use the
string to fish the new wiring back through the unit to the control box.
4
Reclaim the refrigerant from the system.
5
Replace the high pressure switch.
Replace the electrical connection from the high pressure switch to the con-
6
trol box.
7
Replace the filter/dryer, see Figure 37 on page 33.
8
Evacuate the system.
Restore the proper refrigerant charge to the system and verify proper sys-
9
tem operation.
10
Replace the access panel.
Figure 37.
Table 24.
Action
- 33 -
Energize6 Service Manual