S
EPLACING THE
R
H
EPLACING THE
© 2012, IMI Cornelius Inc.
V
B
OLENOID
ALVE
The solenoid valve, shown in Figure 38, is located at the left rear of the unit, behind the
access panel. To replace the solenoid valve body, perform the procedure in Table 26.
Step
1
Turn off the electrical supply to the unit.
2
Remove the access panel from the rear of the unit.
3
Remove the solenoid coil from the valve body.
4
Reclaim the refrigerant from the system.
5
Replace the solenoid valve body.
Replace the solenoid coil by pressing the it onto the valve stem, as shown
6
in Figure 40.
7
Replace the filter/dryer, see Figure 37 on page 33.
8
Evacuate the system.
Restore the proper refrigerant charge to the system and verify proper sys-
9
tem operation.
10
Replace the access panel.
M
EAD
ASTER
The head master is located at the top of the compressor, near the left side of the
unit. To replace the head master, perform the procedure in Table 27.
Step
1
Turn off the electrical supply to the unit.
2
Remove the access panel from the left side of the unit.
3
Drain the bath by removing the overflow tube from the unit.
Thaw the ice bank. This can be accelerated by pouring warm water into the
4
water bath.
5
Reclaim the refrigerant from the system.
Figure 40.
ODY
Table 26.
Action
Table 27.
Action
- 35 -