Replacing Carbonator Pump Pressure Switches; Replacing The Agitator Motor - Cornelius Energize6 Service Manual

Backroom soda chiller package
Table of Contents

Advertisement

Energize6 Service Manual
Replacing Carbon-
ator Pump Pressure
Switches
R
A
EPLACING THE
Publication Number: 621058457SER
Step
10
Turn on the CO
11
Turn on the electrical supply to the unit.
12
Replace the unit cover.
To replace the carbonator pressure switches, perform the procedure in Table 18.
Step
1
Turn off the electrical supply to the unit.
2
Remove the cover using the procedure in "Removing the Unit Cover" on page 14.
3
Drain the system pressure by opening a dispense valve.
4
Turn off the carbonator shutoffs, shown in Figure 22.
Label and remove the pressure switch wires on the sensor being replaced,
5
shown in Figure 24.
6
Remove the malfunctioning pressure switch.
Insert the new pressure switch into the pump, using teflon tape to insure a
7
proper seal.
8
Connect the pressure switch wires to the appropriate switch.
Turn the water supply on and make sure the water bath level is up to the
9
notch in the overflow tube.
10
Open the carbonator shutoffs, shown in Figure 22.
11
Turn on the CO
12
Turn on the electrical supply to the unit.
13
Replace the unit cover.
M
GITATOR
OTOR
The agitator motor is mounted on the top of the unit, on a mounting bracket, shown
in Figure 26.
To remove and replace the agitator motor, perform the procedure in Table 19.
Table 17.
Action
supply to the unit and check the system for leaks.
2
Table 18.
Action
supply to the unit and check the system for leaks.
2
Figure 26.
- 26 -
Tie Wrap
Agitator Motor
Mounting
Bracket