Cornelius Energize6 Service Manual page 24

Backroom soda chiller package
Table of Contents

Advertisement

Energize6 Service Manual
Publication Number: 621058457SER
Step
5
Peel back the insulation on the pump tubing, shown in Figure 16.
6
Remove the inlet and outlet plumbing from the pump, as shown in Figure 17.
Carefully cut the tape holding the two halves of the insulation together
7
around the recirculating pump. (See Figure 17.) Save the insulation.
8
Loosen the retaining collar, shown in Figure 18.
9
Remove the recirculating pump assembly by pulling it away from the motor.
Install the new recirculating pump assembly onto the motor and tighten the
10
pump retaining collar.
11
Reinstall the insulation around the pump and over the pump tubing.
Check and replace the gasket inside the fittings, shown in Figure 14, before
12
reconnecting the pump.
Reconnect the inlet and outlet plumbing to the pump, using teflon tape to
13
insure a proper seal.
Turn the water supply on and make sure the water bath level is up to the
14
notch in the overflow tube.
15
Open the appropriate recirculating shutoff valves, shown in Figure 15.
16
Turn on the CO
2
17
Turn on the electrical supply to the unit.
18
Turn on the water supply to the unit.
19
When the unit is refilled, replace the unit cover.
- 20 -
Table 14.
Action
supply to the unit and check the system for leaks.
Figure 14.
Figure 15.
Circuit 1
Shut off
Valves
Circuit 2
Shutoff
Valves