Replacing The Carbonators - Cornelius Energize6 Service Manual

Backroom soda chiller package
Table of Contents

Advertisement

R
C
EPLACING THE
© 2012, IMI Cornelius Inc.
Ice Probe
Assembly
ARBONATORS
There are two carbonators in the Energize6 unit. To replace a carbonator, perform
the procedure in Table 21.
Step
1
Determine which carbonator is malfunctioning.
2
Turn off the electrical supply to the unit.
3
Turn off the water supply to the unit.
4
Turn off the CO
5
Remove the cover using the procedure in "Removing the Unit Cover" on page 14
6
Drain the bath by removing the overflow tube from the unit.
Thaw the ice bank. This can be accelerated by pouring warm water into the
7
water bath.
8
Drain the system pressure by opening a dispense valve.
To gain access to the carbonator tank, remove the agitator bracket from the
9
unit, as shown in "Replacing the Agitator Motor" on page 26.
10
Carefully slide the bracket out of the way.
Open the carbonator relief valves and depressurize the carbonators,
11
shown in Figure 32.
Figure 30.
Figure 31.
Table 21.
Action
supply to the unit.
2
- 29 -