Co2 Gas Supply; Annually; Water Bath - Cornelius Energize6 Service Manual

Backroom soda chiller package
Table of Contents

Advertisement

CO
Gas Supply
2
A
NNUALLY

Water Bath

© 2012, IMI Cornelius Inc.
!
DANGER:
CO
displaces oxygen. Strict attention MUST be observed in the prevention of CO
2
gas leaks in the entire CO
particularly in a small area, IMMEDIATELY ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentrations of CO
experience tremors which are followed rapidly by loss of consciousness and
DEATH.
system should be inspected and adjusted according to the procedure in
The CO
2
Table 6.
Step
Verify a CO
1
2
Adjust the high pressure regulator, if necessary to obtain the correct pressure
2
settings.
3
Verify a proper pressure setting for the syrup pressure regulators.
Adjust the syrup pressure regulators, if necessary to obtain the correct pres-
4
sure settings.
Inspect the CO
5
The water bath should be inspected and cleaned at least once a year. Perform the
procedure in Table 7 to inspect the water bath.
Step
Remove the cover using the procedure in "Removing the Unit Cover" on
1
page 14.
Use a flashlight or service light to inspect the water and ice for clarity, particles
2
and any algae growth.
3
If the water bath is clean, replace the unit cover.
If the water bath needs to be cleaned, perform the procedure in Table 8.
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures
established by the user. Verify all power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage
to the equipment.
- 13 -
and soft drink system. If a CO
2
Table 6.
Action
high pressure regulator setting of 100 psi (6,8 bar).
system for leaks, and repair as needed.
2
Table 7.
Action
Energize6 Service Manual
gas leak is suspected,
2
2
Publication Number: 621058457SER
2
gas

Advertisement