Step
Unplug the connector and remove the ground wire from the top of the car-
12
bonator, shown in Figure 32.
Label and remove the high and low pressure plumbing connectors from the
13
carbonator, shown in Figure 32.
14
Remove the carbonator from the unit by pulling it straight up out of its mount.
Remove the carbonator tank probe, shown in Figure 33, by unscrewing it
15
from the carbonator.
Place the probe into the new carbonator, making sure that the o-ring seal is
16
in place on the probe.
17
Slide the carbonator into the mount in the unit.
Check and replace the gasket inside the fittings, shown in Figure 14 on
18
page 20, before reconnecting the carbonator plumbing.
Reinstall the plumbing connectors to the carbonator, using teflon tape to
19
insure a proper seal.
20
Reconnect the connector and ground wire to the top of the carbonator.
21
Reinstall the agitator bracket.
Replace the overflow tube, being careful to lubricate the O-rings on the bot-
22
tom of the tube with water before inserting it into the drain.
Turn the water supply on and make sure the water bath level is up to the
23
notch in the overflow tube. Check the drain for water leaks.
24
Turn on the CO
25
Turn on the electrical supply to the unit.
26
When the unit is refilled, replace the unit cover.
Connector
Plumbing
Connections
Ground
Wire
O-Ring
- 30 -
Table 21.
Action
supply to the unit and check the system for leaks.
2
Figure 32.
Figure 33.
Carbonator
Relief
Valve
© 2012, IMI Cornelius Inc.