Cornelius Energize6 Service Manual page 31

Backroom soda chiller package
Table of Contents

Advertisement

© 2012, IMI Cornelius Inc.
Step
1
Turn off the electrical supply to the unit.
2
Remove the cover using the procedure in "Removing the Unit Cover" on page 14.
Unplug the two connectors from the control box, making sure to remove
any tie wraps holding the wiring in place.
TIP: Once all tie wraps have been removed, tie a length of string to the
3
connector before pulling it out of the control board. Then pull the wiring out
of the unit and untie the string. Use the string to fish the new wiring back
through the unit to the control box.
Remove the tie wrap holding the pressure sensor wires to the agitator
4
motor bracket, shown in Figure 26.
Loosen the four screws (two on each side) holding the agitator bracket to
5
the unit, shown in Figure 27.
6
Carefully slide the bracket and remove it.
Place the bracket and pump assembly on a workbench or table and
7
unscrew the impeller blade from the shaft, shown in Figure 28.
8
Remove the slinger off the end of the motor shaft.
Remove the four screws and nuts holding the agitator motor to the mount-
9
ing bracket, shown in Figure 29.
10
Remove the splash guard from the motor, shown in Figure 28.
11
Install the splash guard onto the new motor.
Replace the slinger on the motor shaft and reinstall the impeller blade on
12
the end of the motor shaft.
Mount the motor assembly back onto the mounting bracket using the four
13
screws and nuts.
14
Install the agitator bracket assembly back onto the unit.
15
Replace the electrical connections from the agitator motor to the control box.
16
Turn on the electrical supply to the unit.
17
Replace the unit cover.
Bracket
Mounting
Screws
Splash Guard
Impeller
- 27 -
Table 19.
Action
Figure 27.
Slinger
Figure 28.
Energize6 Service Manual
Agitator
Motor
Publication Number: 621058457SER