Energize6 Service Manual
S
A
ERVICE
CCESS
Removing the Unit
Cover
Publication Number: 621058457SER
Step
1
Turn off the electrical supply to the unit.
2
Turn off the water supply to the unit.
Remove the cover using the procedure in "Removing the Unit Cover" on
3
page 14.
4
Drain the system by opening a dispense valve.
5
Empty the water bath by removing the overflow tube from the unit.
Thaw the ice bank. This can be accelerated by pouring warm water into the
6
water bath.
Carefully spray down the interior of the water bath, the ice coils and the prod-
7
uct coils, if dirty.
8
Fill the bath with a 200ppm chlorinated sanitizing solution.
9
Reconnect the electrical supply to the unit.
10
Turn on the agitator and allow it to run for 10 minutes.
11
Turn off the agitator.
12
Drain all of the sanitizing solution from the water bath.
Thoroughly rinse the bath, the ice coils and the product coils with the same
13
sprayer as used in Step 8.
Replace the overflow tube, being careful to lubricate the O-rings on the bottom
14
of the tube with water.
Turn the water supply on and refill the water bath up to the bottom of the over-
15
flow opening. See "Starting the Unit" on page 6.
16
Check the drain to make sure the overflow tube is not leaking.
17
Turn on the CO
18
Replace the cover on the unit.
The following procedures describe how to service various subsystems and compo-
nents of the Energize6 system.
To remove the top cover from the unit, perform the procedure in Table 9.
Step
Loosen the screw on the left end of the unit, shown in Figure 11.
1
2
Lift the cover up, as shown in Figure 11, and store it in a safe place.
- 14 -
Table 8.
Action
supply to the unit.
2
Table 9.
Action
© 2012, IMI Cornelius Inc.