Cleaning And Sanitizing Procedure; Thawing The Ice Bank - Cornelius Energize6 Service Manual

Backroom soda chiller package
Table of Contents

Advertisement

Energize6 Service Manual
Cleaning and Sanitiz-
ing Procedure
Thawing the Ice
Bank
Publication Number: 621058457SER
Step
5
Rinse the B-I-B disconnects in the sanitizing solution.
Repeat Steps 1-5 for all BIB connectors on the rack. Discard the remaining
6
water from the bucket.
To clean and sanitize the system, perform the procedure in Table 11.
Step
In a 5-gallon container, mix 5 gallons of sanitizing/cleaning solution to manu-
1
facturer's instructions.
Sanitizing fittings must be attached to each B-I-B disconnect. If these fittings
are not available, the fittings from empty B-I-B bags can be cut from the bags
2
and used for this purpose. These fittings open the disconnect so the sanitizing
solution can be drawn through the disconnect.
Place all the B-I-B disconnects into the pail of sanitizing solution. Open each
3
dispenser valve until the sanitizing solution is flowing from the valve.
4
Allow sanitizer to remain in the lines for fifteen (15) minutes.
Remove the nozzle and syrup diffuser from each valve (if equipped) and clean
5
them in a mild detergent solution. Rinse with clean water and reassemble the
nozzle and syrup diffuser to the valve.
Remove the sanitizing fittings from the B-I-B disconnects and connect the dis-
6
connects to the appropriate B-I-B container. Open the valves and let syrup flow
until all sanitizer has been flushed from the system and syrup is flowing freely.
If the unit becomes frozen, it must be carefully Thawed by trained personnel. To
Thaw the Energize6 unit, perform the procedure in Table 12.
Step
1
Turn off the electrical supply to the unit.
2
Turn off the water supply to the unit.
Remove the cover using the procedure in "Removing the Unit Cover" on
3
page 14.
4
Drain the bath by removing the overflow tube from the unit.
Thaw the ice bank. This can be accelerated by pouring warm water into the
5
water bath.
Replace the overflow tube, being careful to lubricate the O-rings on the bottom
6
of the tube with water before inserting it into the drain.
Turn the water supply on and refill the water bath up to the bottom of the over-
7
flow opening.
8
Check the drain to make sure the overflow tube is not leaking.
- 16 -
Table 10.
Action
Table 11.
Action
Table 12.
Action
© 2012, IMI Cornelius Inc.