1-4. INFO MODE (Continued)
1-10
3. OUTPUTS/INPUTS (Continued)
d. "S_F_W_A_ P_ F_" shows in the display. If the output
or input signal is detected, "*" shows beside the letter. Ex:
"S*". If the control senses a problem with the output, "*"
flashes.
Press
to continue onto CPU TMP.
4.
CPU TMP
This step shows the present PC board temperature.
Press
to continue onto cabinet air temperature.
5. CABINET AIR TMP
This step shows the present air temperature inside the cabinet.
Press
to continue onto water heater temperature.
6. WATER HEATER TMP
This step shows the present water heater temperature.
Press
to continue to humidity counts value.
7. HUMIDITY COUNTS VALUE
Factory use only!
Press
to continue onto the humidity value.
8. HUMIDITY VALUE
This step shows the present humidity level inside the cabinet.
Press
to continue onto the analog inputs.
9. ANALOG INPUTS
This step displays the present status of any channel of the
controller's a to d converter. This feature may be useful to a
technician troubleshooting a problem with the controller .
The displayed value can be toggled between Volts and Bits by
pressing
. If the displayed value has a decimal point, it is
voltage (0 to 5 VDC). If no decimal point is shown, the value
is a-to-d bits (0 - 4095).
Model HHC-980/983