2-3. STATS MODE (Continued)
904
ST-13: Highest Humidity Value
Shows the highest humidity value sensed by the humidity
sensor
ST-14: Highest CPU Temperature
Shows the highest control board temperature sensed by the
control
ST-15: Water heater (too hot) cycle count
Shows the number of times the water heater has gotten too hot
ST-16: System Ram - Fade Count
Shows the number of times the system memory has been lost
during power up; ex:
o
ST-17: Hold Ram - Fade Count
Shows the number of times the hold memory has been lost
during a power up; may be lost at a power up, after a power
loss, during a holding cycle
ST-18: Stat Ram - Fade Count
This section shows the number of times the Stats memory has
been lost during power up; the information in the Stats Mode
is updated every two hours, and this count lets you know that
the updates were lost
ST-19: Ram Data Error Count
Shows the number of times the data was lost while operating,
not during power up (should be a low number)
ST-20: Data Total Loss Count
Shows the number of times the data stored in the Eprom has
been lost; should see an "E-41" error code when this occurs
ST-21: User Init's Count
Shows the number of times the operator has initialized the
controls
ST-22: Auto Init's Count
Shows the number of times the controls have automatically
reset
ST-23: Error Log
Records the last 10 errors and the time they occurred; press
to view the log
Model HHC-980/983