Henny Penny HHC-980 Technical Manual page 13

Humidified holding cabinets
Hide thumbs Also See for HHC-980:
Table of Contents

Advertisement

1-4. INFO MODE (Continued)
904
1. E-LOG (error
code log)
Press
and "1A. (date & time) *NOW* shows in display.
This is the present date and time.
Press
and if a error was recorded, "1B. (date, time, and
error code information)" shows in display. This is the latest
error code that the controls recorded.
Press
and the next latest error code information can be
seen. Up to 10 error codes ("1B" to "1K") can be stored in the
E-LOG Section.
Press
to continue to P-LOG.
2. P-LOG (power-up log)
Press
and "2A. (date & time) *NOW* shows in display.
This is the present date and time.
Press
and the latest power-up is shown, "2B. (date, time,)
PWR-UP".
Press
and the next latest power-up date is shown. Up
to 10 power-ups (2B to 2K) can be stored in the P-LOG
section.
Press
to continue onto the outputs/inputs.
3. OUTPUTS/INPUTS
This mode displays the status of components and inputs. If the
input or output signal is detected, an identifying letter is
displayed (see below). If the signal is not detected,
displayed. Press
to view the following:
a. "S_F_W_A_" shows in the display. If the output is on,
"*" shows beside the output letter. Ex: "S*". If the
control senses a problem with the output, "*" flashes.
b. "AMPS S_F_W_A_" shows in the display. A
Checkmark
("
"
) beside the letter indicates normal amps .
A flashing
"X"
beside the letter means a problem exists.
c. "NC/GD S_F_W_A_" shows in the display. This
monitors a possible problem with the relays on the output
PC board. A Checkmark
means everything on the output PC board is good. A
flashing
"X"
beside the letter means a problem exists.
Model HHC-980/983
"_"
("
"
) beside the letter indicates
is
1-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hhc-983

Table of Contents