Henny Penny HHC-980 Technical Manual page 40

Humidified holding cabinets
Hide thumbs Also See for HHC-980:
Table of Contents

Advertisement

3-18. WATER HEATER
REPLACEMENT
(Continued)
Figure 3-49
Figure 3-50
Figure 3-51
Figure 3-52
3-18
8. Locate the aluminum, octagon plate in the kit. Make sure the
surface is free of debris and place the plate over the 4 long studs.
Figure 3-49.
9. Install new heater, making sure the flat side is towards the plate
and the soldered wires are exposed, as shown in Figure 3-50.
10. Install the new insulation from the kit, over the water pan heater .
Figure 3-51.
11. Place new cover plate from the kit, over the insulation.
Figure 3-52.
12. Locate the 12 keps nuts from the kit and place them over the
studs and finger-tighten. Using an 1 1/32" socket or wrench, snug
the nuts down in a cross-fashion, but DO NOT overtighten.
Overtightening the nuts could damage the coating on the heater ,
causing the heater to fail prematurely .
13. Reinstall high limit.
14. Reconnect high limit wires and water pan heater wires to unit.
15. Reinstall water heater cover and water supply , and unit is now
ready for use.
Model HHC-980/983