7: Operating The Device; Operating The Device Using Switches - FIBARO FGRGBW-442 Operating Manual

Rgbw controller 2
Hide thumbs Also See for FGRGBW-442:
Table of Contents

Advertisement

14
7: Operating the device
7.1: Operating the device using switches
Controlling connected loads in RGBW mode (default)
Input can control output only with the same number (e.g. switch
connected to IN1 controls load connected to output OUT1). Per-
form following actions on inputs to change state of the connect-
ed load:
Controlling connected loads in HSB mode
HSB mode is enabled by setting parameter 150 to 1. Inputs
correspond to different components in HSB colour space: IN1
– Hue, IN2 – Saturation, IN3 – Brightness and IN4 input controls
OUT4 output. Perform following actions on inputs to change
values of the components:
operatIng the DevIce
1xclick – change to the opposite one (ON/OFF)
A single click switches between the OFF state and
i
the last non-OFF state. It means it may set the co-
lour back, but the light may not light up as it doesn't
change the brigthness.
2xclick – set colour to 100%
hold/release – dimm/brighten colour
1xclick when value is 0 – restore last set value
1xclick when value is not 0 – set value to 0
2xclick – set value to max
hold/release – increase/decrease value
B
Remember that if the saturation is too low, you may
i
not notice any changes while holding IN1.
More information about the behaviour of the button
i
and HSB mode can be found in our knowledge base.
When you hold the button connected to
IN1, you revolve around the cone on the
H (Hue) axis.
When you hold the button connected to
IN2, you change the saturation (S).
When you hold the button connected to
the IN3, you change the brightness (B).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rgbw controller 2

Table of Contents