7: Operating The Device; Controlling Channels With Inputs; Visual Indications - FIBARO FGS-214 Operating Manual

Hide thumbs Also See for FGS-214:
Table of Contents

Advertisement

7: Operating the device
7.1: Controlling channels with inputs
Momentary switch (parameter 20 set to 0):
1x click – change the state of the channel to the opposite one
Toggle switch without memory (parameter 20 set to 1):
1x switch – change the state of the channel to the state of the switch
(OFF if contacts opened, ON if contacts closed)
Toggle switch with memory (parameter 20 set to 2):
1x switch – change the state of the channel to the opposite one
By default S1 input controls 1st channel and S2 input
i
controls 2nd channel if present. It can be changed us-
ing parameters 24 and 25.
By default outputs are set as NO (normally open).
i
It means the contacts will be opened when turned off
and closed when turned on. It can be switched to NC (nor-
mally closed), which means the contacts will be closed
when turned off and opened when turned on using param-
eters 162/163.
7.2: Visual indications
The built-in LED light shows current device status.
After powering the device:
Green – device added to a Z-Wave network (non-secure, S0, S2
non-authenticated),
Magenta – device added to a Z-Wave network (Security S2
Authenticated),
Red – device not added to a Z-Wave network.
Update:
Blinking cyan – update in progress,
Green – update successful,
Red – update not successful.
Menu:
Blinking green – entering the menu (added as non-secure, S0, S2
non-authenticated),
operatIng the DevIce