21.
This parameter allows to choose mode of 2nd input (IN2). Change
it depending on connected device.
Parameter size 1B
Default value
Available
values
22.
This parameter allows to choose mode of 3rd input (IN3). Change it
depending on connected device.
Parameter size 1B
Default value
Available
values
Input 2 - operating mode
2 (momentary switch)
0 – Analog input without internal pull-up (Sensor
Multilevel)
1 – Analog input with internal pull-up (Sensor
Multilevel)
2 – Momentary switch (Central Scene)
3 – Toggle switch: switch state on every input
change (Central Scene)
4 – Toggle switch: contact closed – ON, contact
opened – OFF (Central Scene)
Input 3 - operating mode
2 (momentary switch)
0 – Analog input without internal pull-up (Sensor
Multilevel)
1 – Analog input with internal pull-up (Sensor
Multilevel)
2 – Momentary switch (Central Scene)
3 – Toggle switch: switch state on every input
change (Central Scene)
4 – Toggle switch: contact closed – ON, contact
opened – OFF (Central Scene)
21