35.
This parameter determines the duration of alarm signaling
(flashing mode and/or alarm sequence).
Parameter size 2B
Default value
Available
values
40.
This parameter defines which actions result in sending scene ID
and attribute assigned to them. Parameter is relevant only if pa-
Actions can be summed up, e.g. 1+2+4+8=15 and entered as a val-
Parameter size 1B
Default value
Available
values
41.
This parameter defines which actions result in sending scene ID
and attribute assigned to them. Parameter is relevant only if pa-
Actions can be summed up, e.g. 1+2+4+8=15 and entered as a val-
Parameter size 1B
Default value
Available
values
Duration of alarm signalization
600 (10min)
0 – infinite signalization
1-32400 (1s-9h, 1s step)
Input 1 - sent scenes
rameter 20 is set to 2, 3 or 4.
ue for the parameter.
15
1 – Key pressed 1 time
2 – Key pressed 2 times
4 - Key pressed 3 times
8 – Key hold down and key released
Input 2 - sent scenes
rameter 21 is set to 2, 3 or 4.
ue for the parameter.
15
1 – Key pressed 1 time
2 – Key pressed 2 times
4 – Key pressed 3 times
8 – Key hold down and key released
25