FIBARO FGRGBW-442 Operating Manual page 27

Rgbw controller 2
Hide thumbs Also See for FGRGBW-442:
Table of Contents

Advertisement

Analog inputs reports and output change on input
63.
This parameter defines minimal change (from the last reported) of
analog input voltage that results in sending new report and change
in the output value. Parameter is relevant only for analog inputs
(parameter 20, 21, 22 or 23 set to 0 or 1).
Parameter size 2B
Default value
Available
values
64.
This parameter defines reporting period of analog inputs value.
Periodical reports are independent from changes in value (param-
Parameter is relevant only for analog inputs (parameter 20, 21, 22
Parameter size 2B
Default value
Available
values
65.
This parameter determines the minimum change in consumed
energy that will result in sending new energy report to the main
controller. Energy reports are sent no often than every 30 seconds.
Parameter size 2B
Default value
Available
values
66.
This parameter determines in what time intervals the periodic
energy reports are sent to the main controller. Periodic reports do
not depend of energy change (parameter 65)
Parameter size 2B
Default value
Available
values
change
5 (0.5V)
0 - reporting on change disabled
1-100 (0.1-10V, 0.1V step)
Analog inputs reports - periodic
eter 63).
or 23 set to 0 or 1).
0 (periodical reports disabled)
0 – periodical reports disabled
30-32400 (30-32400s, 1s step)
Energy reports - on change
10 (0.1 kWh)
0 - reports are disabled
1-500 (0.01 - 5 kWh) - change in energy
Energy reports - periodic
3600 (1h)
0 - periodic reports are disabled
30-32400 (30-32400s) - report interval
27